The MODS method for diagnosis of tuberculosis and multidrug resistant tuberculosis
Published on: August 11, 2008
Diagnostic Accuracy and Utility of FluoroType MTBDR, a New Molecular Assay for Multidrug-Resistant Tuberculosis
Margaretha de Vos1, Brigitta Derendinger1, Tania Dolby2
1DST-NRF Centre of Excellence for Biomedical Tuberculosis Research/South African Medical Research Council Centre for Tuberculosis Research, Division of Molecular Biology and Human Genetics, Faculty of Medicine and Health Sciences, Stellenbosch University, Tygerberg, South Africa.
Abstract:
Most cases of multidrug-resistant (MDR) tuberculosis (TB) are never diagnosed (328,300 of the ∼490,000 cases in 2016 were missed). The Xpert MTB/RIF assay detects resistance only to rifampin, despite ∼20% of rifampin-resistant cases being susceptible to isoniazid (a critical first-line drug). Consequently, many countries require further testing with the GenoType MTBDRplus assay. However, MTBDRplus is not recommended for use on smear-negative specimens, and thus, many specimens require culture-based drug susceptibility testing. Furthermore, MTBDRplus requires specialized expertise, lengthy hands-on time, and significant laboratory infrastructure and interpretation is not automated. To address these gaps, we evaluated the accuracy of the FluoroType MTBDR (FluoroType) assay. Sputa from 244 smear-positive and 204 smear-negative patients with presumptive TB (Xpert MTB positive, n = 343) were tested. Culture and MTBDRplus on isolates served as reference standards (for active TB and MDR-TB, respectively). Sanger sequencing and MTBDRplus, both of which were performed on sputa, were used to resolve discrepancies. The sensitivity of FluoroType for the detection of M. tuberculosis complex was 98% (95% confidence interval [CI], 95 to 99%) and 92% (95% CI, 84 to 96%) for smear-positive and smear-negative specimens, respectively (232/237 versus 90/98 specimens; P < 0.009). The sensitivity and specificity for smear-negative specimens were 100% and 97%, respectively, for rifampin resistance; 100% and 98%, respectively, for isoniazid resistance; and 100% and 100%, respectively, for MDR-TB. FluoroType identified 98%, 97%, and 97% of the rpoB, katG, and inhA promoter mutations, respectively. FluoroType has excellent sensitivity with sputa equivalent to that of MTBDRplus with the isolates and can provide rapid drug susceptibility testing for rifampin and isoniazid. In addition, the capacity of FluoroType to simultaneously identify virtually all mutations in the rpoB, katG, and inhA promoter may be useful for individualized treatment regimens.
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Molecular Models
Accuracy and Precision
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...