An Unusual Cause of Failure to Ventilate
John T Denny1, Sagar S Mungekar1, Benjamin R Landgraf1
1Rutgers University, New Brunswick, NJ, USA.
Abstract:
We report an unusual case of endotracheal tube failure. It was due to a manufacturing defect in the internal white plastic piece that is normally depressed by the luer-lock syringe within the blue pilot balloon. Prior to use, the endotracheal tube was tested and functioned normally. A 64-year-old patient in the intensive care unit with a history of hypertension was being mechanically ventilated after uneventful abdominal surgery. After several hours in the intensive care unit, he was noted to be suddenly no longer receiving adequate tidal volumes from the ventilator. It was found that the cuff on the endotracheal tube was not retaining air when it was filled with air from a syringe. This lead to a large "leak" around the endotracheal tube such that the intended tidal volumes set on the ventilator were not delivered to the patient. The patient was uneventfully reintubated and did well. Subsequent investigation revealed the cause to be a manufacturing defect in the internal white plastic piece that is normally depressed by the luer-lock syringe within the blue pilot balloon. Other mechanisms of cuff failure are reviewed in this case report. This case is an unusual reason for cuff failure. Illustrations supplied alert the reader how to identify the appearance of this manufacturing defect in a pilot balloon. This case illustrates the potential device malfunctions that can develop during a procedure, even when the equipment has been tested and previously functioned well. Even small defects developing in well-engineered products can lead to critical patient care emergencies.
Related Concept Videos
Unusual Results
According to the range rule of thumb, any value above or below two standard deviations, 2σ from the mean, μ is considered unusual.
Maximum unusual value =...
z Scores and Unusual Values
This score indicates how far a value is from the mean in terms of standard deviation. For example, if a data value has a z score of +1, the researcher can infer that the particular data value is one standard deviation above the mean. If another data...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...