Safety-pin Induced Hemopericardium and Cardiac Tamponade in an Infant

Sheeja Sugunan1, A S Ajith Krishnan2, V K Devakumar2

  • 1Department of Pediatrics, SAT Hospital, Government Medical College Thiruvananthapuram, India. Correspondence to: Dr Sheeja Sugunan, Assistant Professor, Department of Pediatrics, SAT, Government Medical College Thiruvananthapuram, India. sheejavimalk@gmail.com.

Indian Pediatrics
|July 7, 2018
PubMed
Abstract

Related Concept Videos

Euler's Formula for Pin-Ended Columns01:21

Euler's Formula for Pin-Ended Columns

In structural engineering, the stability of columns under compressive axial loads is a critical consideration, described as buckling. A typical example involves a column PQ, which is pin-connected at both ends and subjected to a centric axial load F applied at one end, with a reaction force of F' = -F at the other end. Here, it is crucial to understand that when an applied load exceeds the critical load, buckling occurs as the system becomes unstable.
To calculate the critical load, envision...
745
Survey Safety01:28

Survey Safety

Surveying near highways, rough terrain, or power lines involves significant risks. Working along highways is particularly dangerous and requires the use of warning signs and flagmen. It is safest to avoid working directly on roads and use offsets whenever possible. When highway work is unavoidable, it must follow all safety guidelines. Surveyors should wear bright clothing, such as orange reflective vests, to ensure visibility to motorists, coworkers, and hunters. In construction zones, wearing...
413
Household Wiring And Electrical Safety01:13

Household Wiring And Electrical Safety

Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
1.7K
Drug Dosing: Infants and Children01:29

Drug Dosing: Infants and Children

Pediatric patient dosages diverge from adults due to disparities in body surface area, total body water, and extracellular fluid per kilogram of body weight. The dosing regimen considers the variations in pharmacokinetics and pharmacology across distinct age groups, encompassing preterm newborns, infants, young children, older children, and adolescents. Calculation of pediatric patient doses is predicated on determining body surface area, which exhibits a superior correlation with the child's...
309
Cardiac Output II: Effect of Stroke Volume on Cardiac Output01:22

Cardiac Output II: Effect of Stroke Volume on Cardiac Output

Cardiac output (CO), the amount of blood the heart pumps per minute, is a parameter in cardiovascular physiology determined by stroke volume and heart rate. Stroke volume, the amount of blood pushed from one of the ventricles per heartbeat, is influenced by preload, afterload, and contractility.
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
3.5K
Cardiac Output I:Effect of Heart Rate on Cardiac Output01:19

Cardiac Output I:Effect of Heart Rate on Cardiac Output

Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
2.7K