Independent application of an analytical model for secondary neutron equivalent dose produced in a passive-scattering

Kyle J Gallagher1,2, Phillip J Taddei3,4,5

  • 1Oregon Health and Science University, Portland, OR, United States of America.

Related Concept Videos

¹H NMR Chemical Shift Equivalence: Homotopic and Heterotopic Protons01:03

¹H NMR Chemical Shift Equivalence: Homotopic and Heterotopic Protons

Protons in identical electronic environments within a molecule are chemically equivalent and have the same chemical shift. The replacement test is a useful tool to identify chemical equivalence and predict NMR spectra. A substituent replaces each of the protons being examined and the resulting molecules are compared. If the same molecule is obtained, the protons are equivalent or homotopic. Replacement of any hydrogens in ethane by chlorine yields chloroethane because all six protons are...
4.2K
¹H NMR Chemical Shift Equivalence: Enantiotopic and Diastereotopic Protons00:58

¹H NMR Chemical Shift Equivalence: Enantiotopic and Diastereotopic Protons

Replacing each alpha-hydrogen in chloroethane by bromine (or a different functional group) yields a pair of enantiomers. Such protons are called prochiral or enantiotopic and are related by a mirror plane. Enantiotopic protons are chemically equivalent in an achiral environment. Because most proton NMR spectra are recorded using achiral solvents, enantiotopic hydrogens yield a single signal.
In chiral compounds such as 2-butanol, replacing the methylene hydrogens at C3 produces a pair of...
3.3K
Per-Unit Sequence Models01:26

Per-Unit Sequence Models

An ideal Y-Y transformer, grounded through neutral impedances, displays per-unit sequence networks akin to those of a single-phase ideal transformer when subjected to balanced positive- or negative-sequence currents. These currents do not produce neutral currents, and their associated voltage drops.
Zero-sequence currents, which are identical in magnitude and phase, generate a neutral current, resulting in voltage drops across the neutral impedance and the low-voltage winding. If the...
453
Measurement: Derived Units03:02

Measurement: Derived Units

The International System of Units or SI system, by international agreement, has fixed measurement units for seven fundamental properties: length, mass, time, temperature, electric current, amount of substance, and luminosity. These are called the SI base units.
55.8K
Modeling in Therapy01:26

Modeling in Therapy

Modeling, a key technique in therapy, uses observational learning to help clients acquire and practice new skills by watching therapists demonstrate desired behaviors. This approach, rooted in Albert Bandura's concept of vicarious learning, plays a significant role in therapeutic interventions for various psychological conditions, including social anxiety, ADHD, and depression.
Participant Modeling
Participant modeling involves therapists demonstrating calm and effective behaviors in...
484
Equivalent Capacitance01:19

Equivalent Capacitance

Multiple capacitors can be connected in a circuit in series or parallel configuration. When the capacitor combination is connected to a battery, the potential drop across each capacitor and the magnitude of charge stored in the individual capacitor depends on the type of the connection. The capacitor combination is replaced by a single equivalent capacitor that stores the same amount of charge as the combination for a given potential difference.
The following strategies are adopted to calculate...
2.2K