Related Experiment Video
Updated: Feb 8, 2026

HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
[Chromatographic fingerprint analysis of Toosendan Fructus by HPLC-CAD coupled with chemometrics methods]
Abstract:
A new method was developed for the chromatographic fingerprint analysis of Toosendan Fructus by HPLC coupled with the charged aerosol detector (CAD) in the present study. Samples were well separated on an Agilent ZOBAX SB C18 column (4.6 mm × 250 mm, 5 μm) by gradient elution using acetonitrile and water containing 0.1 % formic acid (v/v) at the flow rate of 1.0 mL·min−1. The column temperature was 30 ℃ and the injection volume was 5 μL. The nitrogen inlet pressure of the charged aerosol detector (CAD) was 35 psi, and the nebulizer chamber temperature was 35 ℃. In addition, the method of the chromatographic fingerprints combined with multivariate statistical analysis was effective and reasonable lead to an accurate classification of 20 batches of samples from different locations. The results showed that 28 common peaks were observed in the fingerprint and the samples were classified into three clusters. The established method was well validated, and showed high precision, good repeatability, and satisfactory stability. It may serve in the quality control and evaluation of Toosendan Fructus.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
12:02Automated Modular High Throughput Exopolysaccharide Screening Platform Coupled with Highly Sensitive Carbohydrate Fingerprint Analysis
Published on: April 11, 2016
Related Concept Videos
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
IR Frequency Region: Fingerprint Region
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...