Acquisition and Semi-Automated Analysis of Respiratory Muscle Surface Electromyography
Published on: January 24, 2025
Low-cost electromyography - Validation against a commercial system using both manual and automated activation timing
Sophie Heywood1, Yong Hao Pua2, Jodie McClelland3
1University of the Sunshine Coast, 90 Sippy Downs Drive, Sippy Downs, Queensland 4556, Australia; St Vincent's Hospital Melbourne, Victoria Parade, Melbourne, Victoria 3068, Australia.
Abstract:
Widespread use of electromyography (EMG) as an assessment and biofeedback method may be limited by costly commercial systems. Low-cost devices are available; however their validity is unknown. This study determined the concurrent validity of a low-cost EMG on a microchip compared with a commercially available system during isometric and dynamic muscle contractions. Inter-tester, intra-session reliability of manual data extraction during data processing compared to a simple, automatic thresholding method using the Teager-Kaiser energy operator (TKEO) was also evaluated. 10 healthy women (age 28.1 ± 6.8 yrs, height 162.1 ± 6.8 cm, mass 60.3 ± 10.2 kg) were assessed simultaneously with a commercially available EMG system (Telemyo DTS) and a custom low-cost EMG system (Myoware Muscle Sensor) during voluntary isometric contractions, knee extension, squatting, stepping and jumping. Two surface electrode sets (connected to the low-cost and the commercial system) were placed end to end along the same Vastus Lateralis muscle fibre line. Peak and mean contraction intensity, and contraction duration were analysed. Overall the relative agreement between systems was excellent for peak muscle activation (ICC 0.77-0.96) and modest to excellent for mean muscle activation (ICC 0.68-0.95) and contraction duration (ICC 0.65-0.99). Inter-tester, intra-session reliability was excellent for peak contraction intensity (ICC > 0.99) and modest to excellent for mean contraction intensity, with the TKEO method primarily recording stronger agreement than the manual method. Poor to excellent inter-tester reliability occurred for contraction duration. Our findings indicate that a low-cost EMG system is comparable to a commercial system for assessing muscle activation, and that using the TKEO improved the reliability of timing related variables.
More Related Videos
12:03Antimicrobial Synergy Testing by the Inkjet Printer-assisted Automated Checkerboard Array and the Manual Time-kill Method
Published on: April 18, 2019
08:00Screening for Endocrine Activity in Water Using Commercially-available In Vitro Transactivation Bioassays
Published on: December 4, 2016
Related Concept Videos
Reliability and Validity
Techniques of therapeutic communication I: Active Listening, Sharing Observations, Validation, and Using Touch
Therapeutic communication is not the same as social interaction. Social interaction has no goal or purpose and consists of casual information sharing, whereas therapeutic communication has a plan or purpose for the conversation. Therapeutic...
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...