Related Experiment Video
Updated: Feb 8, 2026

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Contemporary Interventional Radiology Dosimetry: Analysis of 4,784 Discrete Procedures at a Single Institution
Jacob J Bundy1, Jeffrey Forris Beecham Chick2, Anthony N Hage1
1Department of Radiology, Division of Vascular and Interventional Radiology, University of Michigan Health System, Ann Arbor, Michigan.
Purpose:
To report dosimetry of commonly performed interventional radiology procedures and compare dose analogues to known reference levels.
Materials And Methods:
Demographic and dosimetry data were collected for gastrostomy, nephrostomy, peripherally inserted central catheter placement, visceral arteriography, hepatic chemoembolization, tunneled catheter placement, inferior vena cava filter placement, vascular embolization, transjugular liver biopsy, adrenal vein sampling, transjugular intrahepatic portosystemic shunt (TIPS) creation, and biliary drainage between June 12, 2014, and April 26, 2018, using integrated dosimetry software. In all, 4,784 procedures were analyzed. The study included 2,691 (56.2%) male subjects and 2,093 (43.8%) female subjects with mean age 55 ± 21 years (range: 0-104 years) and with mean weight of 76.9 ± 29.4 kg (range: 0.9-268.1 kg). Fluoroscopy time, dose area product (DAP), and reference dose were evaluated.
Results:
TIPS had the highest mean fluoroscopy time (49.1 ± 16.0 min) followed by vascular embolization (25.2 ± 11.4 min), hepatic chemoembolization (18.8 ± 12.5 min), and visceral arteriography (17.7 ± 3.2 min). TIPS had the highest mean DAP (429.2 ± 244.8 grays per square centimeter [Gy·· cm2]) followed by hepatic chemoembolization (354.6 ± 78.6 Gy·· cm2), visceral arteriography (309.5 ± 39.0 Gy·· cm2), and vascular embolization (298.5 ± 29 Gy·· cm2). TIPS was associated with the highest mean reference dose (2.002 ± 1.420 Gy) followed by hepatic chemoembolization (1.746 ± 0.435 Gy), vascular embolization (1.615 ± 0.381 Gy), and visceral arteriography (1.558 ± 1.720 Gy). Of the six procedures available for comparison with the reference levels, the mean fluoroscopy time, DAP, and reference dose for each procedure were below the proposed reference levels.
Conclusion:
Advances in image acquisition technology and radiation safety protocols have significantly reduced the radiation exposure for a variety of interventional radiology procedures.
Related Concept Videos
Contemporary Psychology
Biopsychology
Biopsychology, also known as biological psychology or behavioral neuroscience, focuses on the biological underpinnings of behavior and mental processes. It...
Discrete Fourier Transform
Nursing Interventions I: Taxonomy of Nursing Interventions
A nursing intervention is a treatment or action based on scientific concepts and knowledge from the nursing, behavioral, and physical sciences. Identifying and prioritizing nursing interventions based on the desired outcome...
Nursing Interventions II: Selecting and Classifying the Nursing Interventions
Radiological Investigation I: X-ray and CT
Discrete-time Fourier transform
One of the notable...

