Related Experiment Video
Updated: Feb 8, 2026

Use of Galleria mellonella as a Model Organism to Study Legionella pneumophila Infection
Published on: November 22, 2013
Evaluation of Legiolert for Quantification of Legionella pneumophila from Non-potable Water
Melanie M Rech1, Brian M Swalla2, Jason K Dobranic3
1EMSL Analytical, Inc., 1010 Yuma Street, Denver, CO, 80204, USA. mrech@emsl.com.
Abstract:
Legiolert® is a new culture method for quantification of Legionella pneumophila, which is the primary species associated with Legionnaires' disease. The test is based on a most probable number approach, and differs significantly from traditional culture methods by providing results at 7 days, rapid sample preparation and analysis, and objective interpretation of test results. In this study, we compared the performance of Legiolert with the U.S. Centers for Disease Control and Prevention (CDC) method for detection of L. pneumophila from non-potable samples, primarily comprising cooling tower waters. Our results demonstrated no significant difference between Legiolert and the CDC method for quantification of L. pneumophila. However, Legiolert showed a significant increase in sensitivity when water samples containing higher L. pneumophila concentrations were examined. Cooling tower waters often contain non-Legionella organisms (NLO) that interfere with traditional Legionella test methods, and we observed varying degrees of NLO interference on many CDC method plates. In contrast, Legiolert was resistant to NLO interference and produced a very low rate of false-positive results. Collectively, Legiolert is a sensitive and specific method for quantification of L. pneumophila from non-potable water that provides advantages over the CDC method.
More Related Videos
08:34Legionella pneumophila Outer Membrane Vesicles: Isolation and Analysis of Their Pro-inflammatory Potential on Macrophages
Published on: February 22, 2017
09:12Applying Live Cell Imaging and Cryo-Electron Tomography to Resolve Spatiotemporal Features of the Legionella pneumophila Dot/Icm Secretion System
Published on: March 10, 2020
Related Concept Videos
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
The Water Cycle
Water and Mineral Acquisition
Quality of Water
Regulation of Water Intake
Regulation of Water Output