Changes in conjunctival-scleral thickness after strabismus surgery measured with anterior segment optical coherence
Hiroko Suzuki1, Akiko Hikoya1, Miwa Komori1
1Department of Ophthalmology, Hamamatsu University Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, Japan.
Purpose:
To evaluate changes in conjunctival-scleral thickness following strabismus surgery with anterior segment optical coherence tomography (AS-OCT).
Study Design:
Prospective, observational, consecutive case series.
Methods:
Distances between the conjunctival epithelium and inner scleral wall were measured with AS-OCT before and 3-5 months after strabismus surgery. The measurements were performed at 1.5 mm (limbus), 7.0 mm (insertion), and 8.0 mm (tendon) posterior to the scleral spur on the lateral rectus muscle (LR); and 1.5 mm (limbus), 4.0 mm (insertion), and 5.5 mm (tendon) posterior to the scleral spur on the medial rectus muscle (MR). Thirty-three extraocular muscles (20 LRs and 13 MRs) from 23 subjects were studied.
Results:
Thicknesses were significantly less at the insertion (0.95-0.78 mm; p < 0.001) and tendon (0.99-0.78 mm; p < 0.001) after LR recession and at the tendon (1.21-0.92 mm; p = 0.02) after MR recession. Thicknesses were significantly greater at the insertion (0.82-1.07 mm; p = 0.01) and tendon (0.95-1.28 mm; p = 0.01) after MR resection or plication and at the limbus, insertion, and tendon (0.75-0.90 mm, 0.94-1.19 mm, 1.03-1.28 mm, respectively; all p = 0.04) after LR resection or plication.
Conclusion:
Conjunctival-scleral thicknesses showed various changes after recession and resection or plication. These findings may help detect previous surgical operations when conjunctival scarring and ciliary vessel changes are unclear.
Related Concept Videos
Muscles of the Anterior Neck
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Uncertainty in Measurement: Significant Figures
Properties of Enantiomers and Optical Activity