Related Experiment Video
Updated: Feb 8, 2026

Profiling of Estrogen-regulated MicroRNAs in Breast Cancer Cells
Published on: February 21, 2014
Branched rolling circle amplification method for measuring serum circulating microRNA levels for early breast cancer
Tingting Fan1,2, Yu Mao3, Qinsheng Sun2
1Department of Chemistry, Tsinghua University, Beijing, China.
Abstract:
Serum circulating microRNAs (c-miRNAs) are serving as useful biomarkers for cancer diagnosis. Here, we describe the development of a one-step branched rolling circle amplification (BRCA) method to measure serum c-miRNAs levels for early diagnosis of breast cancer. Four c-miRNAs, c-miRNA16 (c-miR-16), c-miRNA21 (c-miR-21), c-miRNA155 (c-miR-155), and c-miRNA195 (c-miR-195) were isolated from the serum of 49 breast cancer patients and 19 healthy controls. Among them, 45 breast cancer patients and 15 healthy controls were analyzed using one-step BRCA, 4 breast cancer patients and 4 healthy controls were analyzed by quantitative real-time PCR assay [corrected]. The serum levels of c-miR16, c-miR21, c-miR155, and c-miR195 were higher (P < 0.0001) in stage I breast cancer patients than healthy controls. These levels were also higher in several breast cancer molecular subtypes (HER-2 over-expression, Luminal A, Luminal B, and triple negative breast cancer) than in healthy control subjects. The diagnostic accuracy of c-miR16, c-miR21, c-miR155, and c-miR195 for early diagnosis of breast cancer was confirmed by receiver operating characteristic (ROC) curve assay. These results show that the BRCA method can be used to measure serum c-miRNAs levels, and that this method has high accuracy, sensitivity, and specificity. Moreover, both BRCA approach and quantitative real-time PCR (qRT-PCR) method show that the serum levels of c-miR16, c-miR21, c-miR155, and c-miR195 could be used as biomarkers to improve the early diagnosis of breast cancer, and distinguish different breast cancer molecular subtypes.
More Related Videos
Related Concept Videos
MicroRNAs
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Introduction and Methods of Leveling
Circles
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks...
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...