Related Experiment Video
Updated: Feb 8, 2026

A Surgical Procedure for Resecting the Mouse Rib: A Model for Large-Scale Long Bone Repair
Published on: January 21, 2015
Bone Autograft Coupled with Locking Plates Repairs Symptomatic Rib Fracture Nonunions
Abstract:
Symptomatic rib nonunions are a rare complication after rib fractures. Methods used to address these nonunions range from pain management, rib resection, and rib fixation with plates and occasional autologous bone grafting. Given potential complications associated with rib resections such as pulmonary hernia, we hypothesized that plate fixation and autologous bone grafting would yield satisfactory long-term outcomes and a high union rate. Patients (aged ≥18 years) at a single institution with a symptomatic rib nonunion who underwent surgical rib stabilization of the nonunion coupled with bone autograft were evaluated (2010-2014). Pertinent clinical, operative, radiologic, and follow-up data were abstracted. Univariate analyses to assess the relationship of clinical outcomes were performed. Six patients underwent nonunion repair with autograft and plating. The mean time from injury to surgical repair of nonunion was 15 (±6.1) months. A median of 3 [1-3] ribs were repaired with surgery. Postoperative radiographic union was demonstrated on cross-sectional imaging at three months in four patients (57%) and in all patients at five months postoperatively. No patients developed postoperative pulmonary hernia during follow-up. All patients had a significant reduction in median patient-reported pain at follow-up. Surgical rib fixation and bone autograft can provide acceptable outcomes for patients with rib fracture nonunion. This method provides pain relief and promotes healing of the nonunion gap without pulmonary hernia development. Operative fixation and bone autograft should be considered as a viable technical alternative to resection alone for rib nonunion.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
13:16Computed Tomography and Optical Imaging of Osteogenesis-angiogenesis Coupling to Assess Integration of Cranial Bone Autografts and Allografts
Published on: December 22, 2015
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
The Thoracic Cage: Ribs
Parts of a Typical Rib
A typical rib has a head, neck, and body. The posterior end of the rib is called the head, followed by a narrow neck. The head articulates primarily with the costal...
Mismatch Repair
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Overview of DNA Repair
Chemically...
Base Excision Repair
The first step of...