Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
Homogeneous electrochemical aptasensor for mucin 1 detection based on exonuclease I-assisted target recycling
Cuiying Lin1, Huixia Zheng1, Yaying Huang1
1MOE Key Laboratory of Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, Institute of Nanomedicine and Nanobiosensing, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350116, China.
Abstract:
A sensitive and homogeneous electrochemical aptasensor was fabricated for the detection of mucin 1 (MUC1) by combining a well-designed DNA bulge-loop (L-DNA) structure with high-efficient exonuclease I (Exo I)-assisted target recycling amplification strategy. The L-DNA probe was constructed via the hybridization of the MUC1 aptamer and methylene blue (MB) labeled complementary DNA (cDNA) (cDNA-MB) and hence could not diffuse freely to the negatively charged ITO electrode surface due to the strong electrostatic repulsion, so small electrochemical signal was detected. The addition of MUC1 caused the dissociation of L-DNA structure due to the specificity between aptamer and MUC1. Then Exo I was implemented to digest the released cDNA-MB into mononucleotides and then produced short MB-labeled mononucleotides fragments (MB-MFs). As the MB-MFs contained few negative charges, it diffused easily to the negatively charged ITO electrode surface and resulted in the enhanced electrochemical signal. Meanwhile, the MUC1-aptamer complex was also specifically digested by Exo I, resulting in the liberation of MUC1 and hence realized the target recycling and then caused the amplification of the electrochemical signal. The enhanced electrochemical signal has a good linear relationship with logarithm of MUC1 concentration in the range of 1.0 pg mL-1-50 ng mL-1 with a limit of detection of 0.40 pg mL-1 (S/N = 3). Additionally, the fabricated aptasensor has been successfully applied to detect MUC1 in serum samples with satisfactory results and thereby it exhibits great potential in the practical application of clinical diagnosis.
More Related Videos
09:00Electrochemical Detection of Deuterium Kinetic Isotope Effect on Extracellular Electron Transport in Shewanella oneidensis MR-1
Published on: April 16, 2018
06:18Multiplexed Isothermal Amplification Based Diagnostic Platform to Detect Zika, Chikungunya, and Dengue 1
Published on: March 13, 2018
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Test for Homogeneity
Recycling Endosomes and Transcytosis
The recycling endosome is not a single organelle but an extensively tubulated network of recycling pathways. It functions in storing molecules or transporting them across...
Homogeneous Equilibria for Gaseous Reactions
For gas-phase reactions, the equilibrium constant may be expressed in terms of either the molar concentrations (Kc) or partial pressures (Kp) of the reactants and products. A relation between these two K values may be simply derived from the ideal gas equation and the definition of molarity. According to the ideal gas equation:
Tissue Homogenization and Cell Lysis
Mechanical methods of tissue homogenization
These methods rely on applying external physical force to disrupt...
RACE - Rapid Amplification of cDNA Ends