Related Experiment Video
Updated: Feb 8, 2026

Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
Simultaneous Determination of Amphetamine-Related New Psychoactive Substances in Urine by Gas Chromatography-Mass
Jin Young Kim1, Sunglll Suh2, Jaehyeong Park2
1Office of Forensic Science Planning, Supreme Prosecutors' Office, Seoul, Republic of Korea.
Abstract:
Despite the efforts to prevent the spread of new psychoactive substances (NPS) such as synthetic amphetamine derivatives, it is apparent that newer types of NPS are still emerging on the market in recent years. Due to high potential for their abuse, reliable analytical methods are required to determine these substances in biological samples. The objective of this study was to develop and validate the gas chromatography-mass spectrometric (GC-MS) method for the simultaneous determination of 13 amphetamine-related NPS (amphetamine; AP, 4-fluoroamphetamine; 4FA, methamphamine; MA, 4-fluoromethamphetamine; 4FMA, 4-chloroamphetamine; 4CA, para-methoxyamphetamine; PMA, 4-chloromethamphetamine; 4CMA, 6-(2-aminopropyl)benzofuran; 6APB, 4-methylenedioxyamphetamine; MDA, para-methoxymethamphetamine; PMMA, 6-(2-methylaminopropyl)benzofuran; 6MAPB, 3,4-methylenedioxymethamphetamine; MDMA, 5,6-methylenedioxy-2-aminoindane; MDAI) in urine. The analytes were extracted at pH 7.4 by liquid-liquid extraction prior to their trifluoroacetyl derivatives and then analyzed by GC-MS. The validation parameters included selectivity, linearity, lower limits of quantification (LLOQ), intra and interday precision and accuracy, recovery and stability. The linear ranges were 2-100 ng/mL for AP, 4FA, 4FMA, 4CA, PMA, 6APB, MDA, and MDAI, 2-250 ng/mL for 4CMA, PMMA, and 6MAPB and 25-1,000 ng/mL for MA and MDMA, with acceptable coefficients of determination (r2 > 0.9963). The intra and interday precision were within 11.9 and 12.5%, while the intra and interday accuracies ranged from -10.6% to 13.0% and -11.0% to 6.8% for the nominal concentration at all studied levels, respectively. The LLOQs for each analyte were 2.0-25 ng/mL. The recoveries ranged from 69.3% to 96.4%. The short- and long-term variations of the analytes in urine were lower than 8.5 and 12.7%, indicating that the analytes are stable at least for 16 h at room temperature and for 7 days at 4°C, respectively. The applicability of the method was examined by analyzing urine samples from drug abusers and was determined to be effective for detecting multiple drug use.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Chemical Stoichiometry and Gases: Using Ideal Gas Law to Determine Moles
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...