Introduction:
Several ongoing studies aim to improve the survival rate following total knee arthroplasty (TKA), which is an effective orthopedic surgical approach for patients with severely painful knee joint diseases. Among the studied strategies, baseplate rotational arrangement techniques for TKA components have been suggested but have been the subject of only simple reliability evaluations. Therefore, this study sought to evaluate comparatively three different baseplate rotational arrangement techniques that are commonly used in a clinical context.
Materials And Methods:
Three-dimensional (3D) finite element (FE) models of the proximal tibia with TKA were developed and analyzed considering three baseplate rotational arrangement techniques (anterior cortex line, tibial tuberosity one-third line, and tibial tuberosity end line) for six activities of daily life (ADLs) among patients undergoing TKA. Mechanical tests based on the ASTM F1800 standard to validate the FE models were then performed using a universal testing machine. To evaluate differences in biomechanical characteristics according to baseplate rotational arrangement technique, the strain and peak von Mises stresses (PVMSs) were assessed.
Results:
The accuracy of the FE models used in this study was high (94.7 ± 5.6%). For the tibial tuberosity one-third line rotational arrangement technique, strains ≤ 50 µstrain (the critical bone damage strain, which may affect bone remodeling) accounted for approximately 2.2%-11.3% and PVMSs within the bone cement ranged from 19.4 to 29.2 MPa, in ADLs with high loading conditions. For the tibial tuberosity end line rotational arrangement, strains ≤ 50 µstrain accounted for approximately 2.3%-13.3% and PVMSs within the bone cement ranged from 13.5 to 26.7 MPa. For anterior cortex line rotational arrangement techniques, strains ≤50 µstrain accounted for approximately 10.6%-16.6% and PVMSs within the bone cement ranged from 11.6 to 21.7 MPa.
Conclusion:
The results show that the most recently developed frontal cortex line rotational alignment technique is the same or better than the other two rotational alignment techniques in terms of biomechanics. This finding can be, however, dependent on the contact characteristics between the baseplate and the proximal tibia. That is, it is indicated that the optimum baseplate rotational arrangement technique in terms of reducing the incidence of TKA mechanical failure can be achieved by adjusting the characteristics of contact between the baseplate and the proximal tibia.
Related Concept Videos
Fascicle Arrangement in Skeletal Muscles
The four primary types of muscle based on fascicle arrangement are:
Characteristics of Life
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Characteristics of Fluids
Characteristics of BJT
For input characteristics, the base-emitter voltage is varied, maintaining a constant collector-emitter voltage. This setup reveals a Shockley-type dependence of the collector current on...
Characteristics of JFET
The core of a JFET's operation is controlling drain current by modulating the gate-source voltage. When the drain and gate voltage are set to zero, the JFET exhibits no net current flow, representing a state of equilibrium. The drain current increases linearly as the...