Related Experiment Video
Updated: Feb 8, 2026

Author Spotlight: Enhancing Rheumatoid Arthritis Research Through HR-pQCT Imaging Analysis
Published on: October 6, 2023
Development of a scoring method to visually score cortical interruptions on high-resolution peripheral quantitative
Andrea Scharmga1,2,3, Michiel Peters1,2,3, Joop P van den Bergh1,2,4,5
1Department of Rheumatology, Maastricht University Medical Center, Maastricht, The Netherlands.
Objectives:
To develop a scoring method to visually score cortical interruptions in finger joints on High-Resolution peripheral Quantitative Computed Tomography (HR-pQCT), determine its intra- and inter-reader reliability and test its feasibility.
Methods:
The scoring method was developed by integrating results from in-depth discussions with experts, consensus meetings, multiple reading experiments and the literature. Cortical interruptions were scored by two independent readers in an imaging dataset with finger joints from patients with rheumatoid arthritis (RA) and healthy controls and assessed for adjacent trabecular distortion. Reliability for the total number of cortical interruptions per joint and per quadrant was calculated using intraclass correlation coefficient (ICC). Feasibility was tested by recording the time to analyze one joint.
Results:
In 98 joints we identified 252 cortical interruptions, 17% had trabecular distortion. Mean diameter of the interruptions was significantly larger in patients with RA compared with healthy controls (0.88 vs 0.47 mm, p = 0.03). Intra-reader reliability was ICC 0.88 (95% CI 0.83;0.92) per joint and ICC 0.69 (95% CI 0.65;0.73) per quadrant. Inter-reader reliability was ICC 0.48 (95% CI 0.20;0.67) per joint and ICC 0.56 (95% CI 0.49;0.62) per quadrant. The time to score one joint was mean 9.2 (SD 4.9) min.
Conclusions:
This scoring method allows detection of small cortical interruptions on HR-pQCT imaging of finger joints, which is promising for use in clinical studies.
Related Concept Videos
Introduction to z Scores
z scores...
Introduction to z Scores
z scores...
z Scores and Area Under the Curve
z Scores and Unusual Values
This score indicates how far a value is from the mean in terms of standard deviation. For example, if a data value has a z score of +1, the researcher can infer that the particular data value is one standard deviation above the mean. If another data...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

