Related Experiment Video
Updated: Feb 8, 2026

Author Spotlight: Advancing Syphilis Research — Innovations in Treponema pallidum Cultivation and Genetic Engineering
Published on: January 24, 2025
Performance of Treponemal Tests for the Diagnosis of Syphilis
Ina U Park1,2, Yetunde F Fakile2, Joan M Chow1
1Sexually Transmitted Disease Control Branch, Division of Communicable Disease Control, California Department of Public Health, Richmond.
Background:
Treponemal immunoassays are increasingly used for syphilis screening with the reverse sequence algorithm. There are few data describing performance of treponemal immunoassays compared to traditional treponemal tests in patients with and without syphilis.
Methods:
We calculated sensitivity and specificity of 7 treponemal assays: (1) ADVIA Centaur (chemiluminescence immunoassay [CIA]); (2) Bioplex 2200 (microbead immunoassay); (3) fluorescent treponemal antibody absorption test (FTA-ABS); (4) INNO-LIA (line immunoassay); (5) LIAISON CIA; (6) Treponema pallidum particle agglutination assay (TPPA); and (7) Trep-Sure (enzyme immunoassay [EIA]), using a reference standard combining clinical diagnosis and serology results. Sera were collected between May 2012-January 2013. Cases were characterized as: (1) current clinical diagnosis of syphilis: primary, secondary, early latent, late latent; (2) prior treated syphilis only; (3) no evidence of current syphilis, no prior history of syphilis, and at least 4 of 7 treponemal tests negative.
Results:
Among 959 participants, 262 had current syphilis, 294 had prior syphilis, and 403 did not have syphilis. FTA-ABS was less sensitive for primary syphilis (78.2%) than the immunoassays or TPPA (94.5%-96.4%) (all P ≤ .01). All immunoassays were 100% sensitive for secondary syphilis, 95.2%-100% sensitive for early latent disease, and 86.8%-98.5% sensitive in late latent disease. TPPA had 100% specificity.
Conclusions:
Treponemal immunoassays demonstrated excellent sensitivity for secondary, early latent, and seropositive primary syphilis. Sensitivity of FTA-ABS in primary syphilis was poor. Given its high specificity and superior sensitivity, TPPA is preferred to adjudicate discordant results with the reverse sequence algorithm over the FTA-ABS.
Related Concept Videos
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters...
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...
Diabetes: Symptoms, Diagnosis, and Complications
Pathophysiology of Cardiac Performance

