Investigation of A Slow-Light Enhanced Near-Infrared Absorption Spectroscopic Gas Sensor, Based on Hollow-Core

Zhi-Fa Wu1, Chuan-Tao Zheng2, Zhi-Wei Liu3

  • 1State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, 2699 Qianjin Street, Jilin University, Changchun 130012, China. wuzf@jlu.edu.cn.

Related Concept Videos

Band Theory02:35

Band Theory

When two or more atoms come together to form a molecule, their atomic orbitals combine and molecular orbitals of distinct energies result. In a solid, there are a large number of atoms, and therefore a large number of atomic orbitals that may be combined into molecular orbitals. These groups of molecular orbitals are so closely placed together to form continuous regions of energies, known as the bands.
The energy difference between these bands is known as the band gap.
Conductor, Semiconductor,...
17.2K
Light as Energy01:35

Light as Energy

The energy required to carry out photosynthesis is light— typically electromagnetic radiation from the sun. The range of all possible wavelengths is known as the electromagnetic spectrum.
Photons
A photon is a discrete electromagnetic particle or bundle of energy. Photons are characterized by their frequency, wavelength, and amplitude, similar to the properties of a wave. Waves with higher frequencies transmit more energy and have shorter wavelengths than longer wavelengths that transmit...
96.0K
Atomic Absorption Spectroscopy: Radiation and Light Sources01:13

Atomic Absorption Spectroscopy: Radiation and Light Sources

Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
1.3K
The Nucleosome Core Particle02:10

The Nucleosome Core Particle

Nucleosomes are the DNA-histone complex, where the DNA strand is wound around the histone core. The histone core is an octamer containing two copies of H2A, H2B, H3, and H4 histone proteins.
The paradox
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their main responsibility is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. While on the other hand, they must allow polymerase enzymes to access DNA...
14.5K
Classification of Skeletal Muscle Fibers01:48

Classification of Skeletal Muscle Fibers

Skeletal muscles continuously produce ATP to provide the energy that enables muscle contractions. Skeletal muscle fibers can be categorized into three types based on differences in their contraction speed and how they produce ATP, as well as physical differences related to these factors. Most human muscles contain all three muscle fiber types, albeit in varying proportions.
Slow-Twitch Muscle Fibers
Slow oxidative, muscle fibers appear red due to large numbers of capillaries and high levels of...
59.6K
Gap Junctions01:37

Gap Junctions

Multicellular organisms employ a variety of ways for cells to communicate with each other. Gap junctions are specialized proteins that form pores between neighboring cells in animals, connecting the cytoplasm between the two, and allowing for the exchange of molecules and ions. They are found in a wide range of invertebrate and vertebrate species, mediate numerous functions including cell differentiation and development, and are associated with numerous human diseases, including cardiac and...
57.2K