Related Experiment Video
Updated: Feb 8, 2026

A Rabbit Aortic Valve Stenosis Model Induced by Direct Balloon Injury
Published on: March 31, 2023
Intrapulmonary Vein Ablation Without Stenosis: A Novel Balloon-Based Direct Current Electroporation Approach
Chance M Witt1, Alan Sugrue1, Deepak Padmanabhan1
1Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN.
Background:
Current thermal ablation methods for atrial fibrillation, including radiofrequency and cryoablation, have a suboptimal success rate. To avoid pulmonary vein (PV) stenosis, ablation is performed outside of the PV, despite the importance of triggers inside the vein. We previously reported on the acute effects of a novel direct current electroporation approach with a balloon catheter to create lesions inside the PVs in addition to the antrum. In this study, we aimed to determine whether the effects created by this nonthermal ablation method were associated with irreversible lesions and whether PV stenosis or other adverse effects occurred after a survival period.
Methods And Results:
Initial and survival studies were performed in 5 canines. At the initial study, the balloon catheter was inflated to contact the antrum and interior of the PV. Direct current energy was delivered between 2 electrodes on the catheter in ECG-gated 100 μs pulses. A total of 10 PVs were treated demonstrating significant acute local electrogram diminution (mean amplitude decrease of 61.2±19.8%). After the survival period (mean 27 days), computed tomography imaging showed no PV stenosis. On histologic evaluation, transmural, although not circumferential, lesions were seen in each treated vein. No PV stenosis or esophageal injury was present.
Conclusions:
Irreversible, transmural lesions can be created inside the PV without evidence of stenosis after a 27-day survival period using this balloon-based direct current ablation approach. These early data show promise for an ablation approach that could directly treat PV triggers in addition to traditional PV antrum ablation.
Related Concept Videos
Mitral Stenosis I: Introduction
Veins
Structure of Veins:
The structure of veins is specifically designed to assist in the low-pressure transportation of...
Electrical Current
Veins of Thorax
The azygos vein, positioned just right of the midline and anterior to the vertebral column, begins at the junction of the right ascending lumbar and subcostal veins, terminating in the superior vena cava. This vein drains blood from the right side of the thoracic wall, thoracic viscera, and posterior abdominal wall.
The...
Veins of Lower Limbs
Formed by the union of the medial and lateral plantar veins, the posterior tibial vein, rising through the calf muscle, assimilates the fibular vein. The anterior tibial vein, a superior extension of the foot's dorsalis pedis vein, merges with the posterior tibial vein at the...
Mitral Stenosis III: Medical Management