Related Experiment Video
Updated: Feb 8, 2026

Intraoperative Ultrasound in Spinal Surgery
Published on: August 17, 2022
Systematic re-evaluation of intraoperative motor-evoked potential suppression in scoliosis surgery
Yew Long Lo1,2, Yam Eng Tan3, Sitaram Raman3
11Department of Neurology, National Neuroscience Institute, Singapore General Hospital, Outram Road, Academia Level 4, Singapore, 169608 Singapore.
Background:
Motor- (MEP) and somatosensory-evoked potentials (SSEP) are susceptible to the effects of intraoperative environmental factors.
Methods:
Over a 5-year period, 250 patients with adolescent idiopathic scoliosis (AIS) who underwent corrective surgery with IOM were retrospectively analyzed for MEP suppression (MEPS).
Results:
Our results show that four distinct groups of MEPS were encountered over the study period. All 12 patients did not sustain any neurological deficits postoperatively. However, comparison of groups 1 and 2 suggests that neither the duration of anesthesia nor speed of surgical or anesthetic intervention were associated with recovery to a level beyond the criteria for MEPS. For group 3, spontaneous MEPS recovery despite the lack of surgical intervention suggests that anesthetic intervention may play a role in this process. However, spontaneous MEPS recovery was also seen in group 4, suggesting that in certain circumstances, both surgical and anesthetic intervention was not required. In addition, neither the duration of time to the first surgical manoeuver nor the duration of surgical manoeuver to MEPS were related to recovery of MEPS. None of the patients had suppression of SSEPs intraoperatively.
Conclusion:
This study suggests that in susceptible individuals, MEPS may rarely occur unpredictably, independent of surgical or anesthetic intervention. However, our findings favor anesthetic before surgical intervention as a proposed protocol. Early recognition of MEPS is important to prevent false positives in the course of IOM for spinal surgery.
More Related Videos
10:31Intraoperative Gastroscopy for Tumor Localization in Laparoscopic Surgery for Gastric Adenocarcinoma
Published on: August 9, 2016
11:05Tissue-simulating Phantoms for Assessing Potential Near-infrared Fluorescence Imaging Applications in Breast Cancer Surgery
Published on: September 19, 2014
Related Concept Videos
Random and Systematic Errors
Systematic Sampling Method
Systematic sampling is one of the simplest methods...
Propagation of Uncertainty from Systematic Error
Potential Energy
Chemical bonds that form attractive forces between atoms also contain potential energy, called chemical energy. When a chemical reaction...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Standard Electrode Potentials