Purpose:
To investigate the changes in higher-order aberrations (HOAs) induced by the implantation of implantable collamer lenses (ICLs) and Toric ICL (TICL) in eyes with high myopia and high myopic astigmatism.
Methods:
We investigated 33 eyes of 18 consecutive patients (in a prospective, interventional case series study), with spherical equivalent errors of -6.00 to -21.09 diopters (D) and cylindrical errors of -0.5 to -4.75 D, who underwent ICL and TICL implantation. Before and after 5 days, 2 and 6 months of surgery, the uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), defocus and adverse events of the surgery were assessed. Ocular HOAs were also evaluated by Hartmann-Shack aberrometry (Technolas PV, Rochester, New York, USA) before and after 6 months of surgery.
Results:
At 6.0 months after surgery, the UCVA and BCVA in 40% and 66.7% of eyes were 20/20, respectively. Mean defocus refraction and astigmatism was reduced to -0.66 and 0.65 D from -12.79 and 2.18 at baseline, respectively. For a 6 mm pupil, HOAs were not significantly changed, merely from 0.417 ± 0.162 μ before surgery to 0.393 ± 0.119 μ after surgery (P = 0.45). Spherical aberration (Z400) increased significantly (P = 00.0). Surgical induced astigmatism was lower than 0.25 D, and there were no changes in trefoils and coma aberration. No vision-threatening complications occurred during the observation period.
Conclusion:
This study shows that the ICL and TICL performed well in correcting high myopic astigmatism without significant changes in HOAs during a 6-month observation period, although the spherical aberration (Z400) increased significantly.
More Related Videos
11:11Stereotaxic Viral Injection and Gradient-Index Lens Implantation for Deep Brain In Vivo Calcium Imaging
Published on: October 8, 2021
10:00Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks
Published on: February 14, 2015
Related Concept Videos
Cleavage and Blastulation
Reproductive Cloning
Somatic Cell Nuclear Transfer
In SCNT, an egg cell is taken from an animal and its nucleus is removed, creating an enucleated egg. Then a somatic...
Bacterial Signaling
In-vitro Mutagenesis
Nucleotide Excision Repair
DNA-only Transposons
The donor site from where the transposon is excised is either degraded or...