Related Experiment Videos
GLC determination of indoprofen in plasma
Journal of Pharmaceutical Sciences
|January 1, 1977
Summary
A new method accurately measures indoprofen in blood plasma for bioavailability studies. This sensitive assay ensures reliable drug concentration monitoring in human subjects.
Area of Science:
- Pharmacokinetics
- Analytical Chemistry
- Drug Metabolism
Background:
- Human bioavailability studies for the analgesic indoprofen necessitate a precise and efficient analytical method.
- Existing methods may lack the required sensitivity or convenience for plasma drug level monitoring.
Purpose of the Study:
- To develop and validate a rapid, sensitive, and convenient assay for quantifying indoprofen in human blood plasma.
- To support human bioavailability studies by providing reliable plasma concentration data.
Main Methods:
- Ether extraction of acidified plasma samples.
- Derivatization of extracted indoprofen using diazomethane.
- Gas-liquid chromatography (GLC) analysis utilizing a 3% OV-1 column.
Main Results:
- The developed assay demonstrated sufficient sensitivity for measuring indoprofen concentrations in the range of 0.4-16 µg/ml.
- An average recovery rate of 99.0% ± 7.6% was achieved.
- The pentanoic acid homolog proved effective as an internal standard.
Conclusions:
- The described ether extraction, diazomethane derivatization, and GLC method is suitable for the determination of indoprofen in human plasma.
- This assay provides a reliable tool for pharmacokinetic and bioavailability assessments of indoprofen.