Related Experiment Video
Updated: Feb 8, 2026

Author Spotlight: PEGASOS Tissue Clearing Technique to Visualize Bone Remodeling
Published on: August 18, 2023
FAN1 protects against repeat expansions in a Fragile X mouse model
1Section on Gene Structure and Disease, Laboratory of Cell and Molecular Biology, National Institute of Diabetes, Digestive and Kidney Diseases, National Institutes of Health, Bethesda, MD, 20892, United States.
None:
The Fragile X-related disorders (FXDs) are members of a large group of human neurological or neurodevelopmental conditions known as the Repeat Expansion Diseases. The mutation responsible for all of these diseases is an expansion in the size of a disease-specific tandem repeat tract. However, the underlying cause of this unusual mutation is unknown. Genome-wide association studies have identified single nucleotide polymorphisms (SNPs) in the vicinity of the FAN1 (MIM* 613534) gene that are associated with variations in the age at onset of a number of Repeat Expansion Diseases. FAN1 is a nuclease that has both 5'-3' exonuclease and 5' flap endonuclease activities. Here we show in a model for the FXDs that Fan1-/- mice have expansions that, in some tissues including brain, are 2-3 times as extensive as they are in Fan1+/+ mice. However, no effect of the loss of FAN1 was apparent for germ line expansions. Thus, FAN1 plays an important role in protecting against somatic expansions but is either not involved in protecting against intergenerational repeat expansions or is redundant with other related enzymes. However, since loss of FAN1 results in increased expansions in brain and other somatic tissue, FAN1 polymorphisms may be important disease modifiers in those Repeat Expansion Diseases in which somatic expansion contributes to age at onset or disease severity.
Related Concept Videos
Heat and Free Expansion
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Protecting Self-Esteem
Thermal Expansion

