Related Experiment Video
Updated: Feb 8, 2026

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Real-Time FEM-Based Registration of 3-D to 2.5-D Transrectal Ultrasound Images
Abstract:
We present a novel technique for real-time deformable registration of 3-D to 2.5-D transrectal ultrasound (TRUS) images for image-guided, robot-assisted laparoscopic radical prostatectomy (RALRP). For RALRP, a pre-operatively acquired 3-D TRUS image is registered to thin-volumes comprised of consecutive intra-operative 2-D TRUS images, where the optimal transformation is found using a gradient descent method based on analytical first and second order derivatives. Our method relies on an efficient algorithm for real-time extraction of arbitrary slices from a 3-D image deformed given a discrete mesh representation. We also propose and demonstrate an evaluation method that generates simulated models and images for RALRP by modeling tissue deformation through patient-specific finite-element models (FEM). We evaluated our method on in-vivo data from 11 patients collected during RALRP and focal therapy interventions. In the presence of an average landmark deformation of 3.89 and 4.62 mm, we achieved accuracies of 1.15 and 0.72 mm, respectively, on the synthetic and in-vivo data sets, with an average registration computation time of 264 ms, using MATLAB on a conventional PC. The results show that the real-time tracking of the prostate motion and deformation is feasible, enabling a real-time augmented reality-based guidance system for RALRP.].
More Related Videos
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
ortho–para-Directing Activators: –CH3, –OH, –⁠NH2, –OCH3
Real Number System
Real Number Operations
Ions as Acids and Bases
Salts are ionic compounds composed of cations and anions, either of which may be capable of undergoing an acid or base ionization reaction with water. Aqueous salt solutions, therefore, may be acidic, basic, or neutral, depending on the relative acid-base strengths of the salt’s constituent ions. For example, dissolving the ammonium chloride in water results in its dissociation, as described by the equation: