Simultaneous Azimuth and Fresnel Elevation Compounding: A Fast 3-D Imaging Technique for Crossed-Electrode Arrays
Abstract:
We have developed a new, fast, and simple 3-D imaging approach referred to as Simultaneous Azimuth and Fresnel Elevation (SAFE) compounding using a bias-sensitive crossed-electrode array. The principle behind this technique is to perform conventional plane-wave compounding with a back set of electrodes, while implementing a reconfigurable Fresnel elevation lens with an orthogonal set of front electrodes. While a Fresnel lens would usually result in unacceptable secondary lobe levels, these lobes can be suppressed by compounding different Fresnel patterns. The azimuthal and elevational planes can be simultaneously compounded to increase the beam quality with no loss in frame rate. A 10-MHz, $64 \times 64$ element crossed-electrode relaxor array was fabricated on an electrostrictive one-to-three composite substrate to demonstrate the SAFE compounding approach. The electrostrictive composite array has a measured electromechanical coupling coefficient ( $k_{t}$ ) of 0.62 with a bias voltage of 90 V and a measured two-way pulse bandwidth of 60%. The electrical impedance magnitude of array elements on resonance was measured to be $90~\Omega$ with a phase angle of -35°. Radiation patterns were simulated showing a -6-dB beamwidth of $330~\mu \text{m}$ with secondary lobe levels suppressed more than -60 dB in the azimuth dimension, and a -6-dB beamwidth of $450~\mu \text{m}$ with secondary lobe levels suppressed to -50 dB in the elevation dimension after 64 compounds. Experimental radiation patterns were collected and found to be in good agreement with simulations. Experimental 3-D images of wire phantoms were collected using a Verasonics experimental ultrasound system.
Related Concept Videos
Azimuths and Bearings
β-Dicarbonyl Compounds via Crossed Claisen Condensations
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
Cross-Sectional Research
Standard Electrode Potentials
Crossing Over
The homologous pairs of sister chromosomes—one from the maternal and one from the paternal genome—then begin to align alongside each other lengthwise, matching corresponding DNA positions in a process...


