Related Experiment Video
Updated: Feb 7, 2026

E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
A novel device for intracolonoscopy cleansing of inadequately prepared colonoscopy patients: a feasibility study
Kelly E van Keulen1, Helmut Neumann2, Jörn M Schattenberg2
1Department of Gastroenterology and Hepatology, Radboud University Medical Center, Nijmegen, the Netherlands.
Background:
The importance of high quality preprocedural bowel preparation is widely acknowledged, but suboptimal bowel cleansing still occurs in up to 20 % of all colonoscopy patients. The aim of this study was to evaluate the performance of a novel intraprocedural cleaning device for cleaning poorly prepared colons.
Methods:
This multicenter feasibility study included patients aged 18 - 75 years who were referred for colonoscopy. Intraprocedural cleaning was performed in patients after a limited preprocedural bowel preparation regimen (2 days of dietary restrictions and 2 × 10 mg bisacodyl). The primary outcome was the proportion of adequately prepared patients (Boston Bowel Preparation scale [BBPS] ≥ 2 in each segment) before and after segmental washing with the new device. Secondary outcomes included: cecal intubation rate, procedure time, system usability, patient satisfaction, and safety.
Results:
47 patients (42.6 % male), with a median age of 61 years (interquartile range [IQR] 46 - 67 years), were included at three clinical sites. Cecal intubation was achieved in 46/47 patients (97.9 %). The cleaning device significantly improved the proportion of patients with adequate bowel cleansing (from 19.1 % to 97.9 %; P < 0.001) and median BBPS score (from 3.0 [IQR 0.0 - 5.0] to 9.0 [IQR 8.0 - 9.0]). Median cecal intubation time and total procedure time were 16.5 minutes (IQR 9.0-28.3) and 34.0 minutes (IQR 25.0 - 42.8), respectively. Physicians were satisfied with the ease of use of the device and it was well tolerated by patients. No severe adverse events occurred during the study period.
Conclusions:
This feasibility study suggests that the intraprocedural cleaning device appears to be safe and effective in cleaning poorly prepared colons to an adequate level, allowing a thorough colorectal examination.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
07:06Fecal Microbiota Transplantation via Colonoscopy for Recurrent C. difficile Infection
Published on: December 8, 2014
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Bioavailability Study Design: Healthy Subjects Versus Patients
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...
Patient-centered Care