Accuracy of iohexol plasma clearance for GFR-determination: a comparison between single and dual sampling
Yong Zhang1, Zhun Sui1, Ze Yu2
1Department of Nephrology, Peking University People's Hospital, No. 11 Xizhimen South Street, Xi Cheng District, Beijing, 100044, China.
Background:
Current guidelines regarding plasma-sampling techniques for glomerular filtration rate (GFR) determination are inconsistent. Single-sample methods are commonly believed not to be precise enough to meet clinical demands. The present study compared the agreement between single- and dual- plasma sampling methods with a three-point plasma clearance of iohexol.
Methods:
A total of 46 healthy volunteers and 124 chronic kidney disease (CKD) patients with varying degrees of renal dysfunction received 5 ml iohexol (300 mgI/ml) i.v. and plasma samples were drawn at 2-, 3- and 4-h post-injection. Plasma-iodine concentrations were detected by high-performance liquid chromatography (HPLC).
Results:
Bias was similar among single-plasma sampling methods (SPSM) and dual-plasma sampling methods (DPSM). The best correlation was obtained from the 2- and 4-h DPSM (concordance correlation coefficient [CCC]: 0.9988) with none of the estimates differed by more than 30% from the reference GFR and only one (0.06%) estimate differed by more than 10% (P30, 100%; P10, 99.4%). SPSM using samples around 3- or 4-h demonstrated acceptable accuracy at a GFR level of ≥60 ml/min/1.73m2 (P30 = 100% and P10 > 75% for both measurements).
Conclusion:
4-h SPSM is advantageous in clinical practice in subjects with GFR ≥ 60 ml/min/1.73m2. For patients with an expected GFR < 60 ml/min/1.73m2, a prolonged sampling time is more reliable.
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Improving Translational Accuracy
Factors Affecting Renal Clearance: Drug's Physicochemical Properties and Plasma Levels
One important factor is the drug's molecular size. The kidneys readily excrete smaller molecules below 300 Daltons (Da). On the other hand, molecules weighing between 300 and 500 Da are excreted through both urine and bile. Larger molecules above 500 Da tend to be excreted...
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision