Related Experiment Video
Updated: Feb 7, 2026

A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
A Two-test Protocol for the Precise Determination of the Maximal Lactate Steady State
Daniel Yaeger1, Kristi Murphy1, Jena Winger1
1Department of Exercise Science, Willamette University, Salem, OR, USA.
Abstract:
The purpose of this study was to determine the efficacy of a two-test method for precisely identifying the Maximal Lactate Steady State (MLSS). Eight male competitive cyclists performed two bouts on a cycle ergometer. Following a maximal oxygen consumption (V̇O2max) test (66.91 ± 5.29 mL·kg-1·min-1) we identified the lactate deflection point using the visual deflection (TVis), Log-Log (TLog), Dmax (TDmax), RER = 1.00 (TRER), ventilatory threshold (TVent), and the 1.0 mmol·L-1 increase above baseline (T+1) methods. The second incremental test (SIT) consisted of 6-7 stages (5 min each) starting 20-30 W below to 20-30 W above the predetermined deflection point, in 10 W increments. Comparison of the two tests yielded different threshold estimates (range 11-46W) for all methods (P = 0.001-0.019) except the TLog (P = 0.194) and TRER (P = 0.100). The SIT resulted in significantly (P = 0.007) more narrow range of thresholds (27.5 ± 11.01W) compared to the V̇O2max test (70 ± 42.51W). The TVis from the SIT was identified as the MLSS and was verified using three 45-minute steady-state exercise bouts at 95%, 100%, and 105% of MLSS intensity (average increment 12.8 W). Blood lactate and V̇O2 were recorded every 5 minutes and differed between the three intensities at every time point (P < 0.001). V̇O2 increased from the 5th to the 45th minute by 7.02 mL·kg-1·min-1 (100% MLSS), 3.63 mL·kg-1·min-1 (95% MLSS) and 7.5 mL·kg-1·min-1 (105% MLSS, to the 30th minute). These results indicate that the MLSS was identified correctly by the SIT, the single incremental test overestimated the MLSS intensity, and the TVis provides a very accurate determination of the lactate breakpoint. The use of a second submaximal test is required for a precise identification of MLSS.
Related Concept Videos
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Steady State Concentration
Most drugs are administered in repeated doses at fixed intervals or through continuous...
Steady Flow of a Fluid Stream
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
Transient and Steady-state Response
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
Velocity and Acceleration in Steady and Unsteady Flow
The acceleration can be generalized to any point in the flow, and expressed as components along three perpendicular directions, representing changes in velocity over...
Uncertainty in Measurement: Accuracy and Precision

