Related Experiment Video
Updated: Feb 7, 2026

E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Can Water Exchange Improve Patient Tolerance in Unsedated Colonoscopy A Prospective Comparative Study
Richard Azevedo1, Cátia Leitão1, João Pinto1
1Department of Gastroenterology, Amato Lusitano Hospital, Castelo Branco, Portugal.
Background & Aims:
Unsedated colonoscopy can be painful, poorly tolerated by patients, and associated with unsatisfactory technical performance. Previous studies report an advantage of water exchange over conventional air insufflation in reducing pain during unsedated colonoscopy. Our goal was to analyze the impact of water exchange colonoscopy on the level of maximum pain reported by patients submitted to unsedated colonoscopy, compared to conventional air insufflation.
Methods:
We performed a single-center, patient-blinded, prospective randomized comparative study, where patients were either allocated to the water group, in which the method of colonoscopy used was water exchange, or the standard air group, in which the examination was accomplished with air insufflation.
Results:
A total of 141 patients were randomized, 70 to the water and 71 to the air group. The maximum level of pain reported by patients during unsedated colonoscopy, measured by a numeric scale of pain (0-10), was significantly lower in the water group (3.39 ± 2.32), compared to the air group (4.94 ± 2.10), p < 0.001. The rate of painless colonoscopy was significantly higher in the water group (12.9 vs. 1.4%, p = 0.009). There were no significant differences between the two groups regarding indications for the procedure, quality of bowel preparation, cecal intubation time, withdrawal time, number of position changes, adenoma detection rate, and postprocedural complications. Only the number of abdominal compressions was significantly different, showing that water exchange decreases the number of compressions needed during colonoscopy.
Conclusions:
Water exchange was a safe and equally effective alternative to conventional unsedated colonoscopy, associated with less intraprocedural pain without impairing key performance measures.
Related Concept Videos
Social Exchange Theory
Social Exchange Theory
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Comparative Excretory Systems
Gas Exchange and Transport

