Simultaneous Determination of Inorganic Cations and Anions in Microchip Electrophoresis Using High-voltage Relays

Zhe Huang1,2, Mingpeng Yang1,2, Hui You1,2

  • 1Institute of Intelligent Machines, Chinese Academy of Sciences.

Related Concept Videos

π Molecular Orbitals of the Allyl Cation and Anion01:18

π Molecular Orbitals of the Allyl Cation and Anion

An allyl group is a three-carbon conjugated system where the sp³-hybridized allylic carbon is bonded to a CH=CH2 group via a single bond. Allyl anions can be obtained by treating propene with a strong base that can deprotonate methyl groups. Allyl cations are formed as intermediates during substitution reactions involving allylic halides. In both cases, the hybridization of the allylic carbon changes from sp3 to sp2, giving rise to a carbon chain with three sp2-hybridized carbons, each with...
5.6K
Determining the pH of Salt Solutions04:08

Determining the pH of Salt Solutions

The pH of a salt solution is determined by its component anions and cations. Salts that contain pH-neutral anions and the hydronium ion-producing cations form a solution with a pH less than 7. For example, in ammonium nitrate (NH4NO3) solution, NO3− ions do not react with water whereas NH4+ ions produce the hydronium ions resulting in the acidic solution.  In contrast, salts that contain pH-neutral cations and the hydroxide ion-producing anions form a solution with a pH greater than 7. For...
48.2K
Directional Relays01:25

Directional Relays

Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
620
Overcurrent Relays01:26

Overcurrent Relays

Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
549
Differential Relays01:20

Differential Relays

Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
779
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.