Related Experiment Video
Updated: Feb 7, 2026

Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
Quantitative determination of armodafinil in human plasma by liquid chromatography-electrospray mass spectrometry:
Hardik Chandasana1, Johannes Kast1, Janina A Bittman1
1Department of Pharmaceutics, University of Florida, Gainesville, Gainesville, Florida, USA.
Abstract:
Armodafinil is a wake-promoting agent approved in 2007 by the US Food and Drug Administration for the treatment of excessive sleepiness. A rapid, sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of armodafinil in human plasma was developed and validated. Armodafinil and internal standard (armodafinil d-10) were extracted from human plasma using protein precipitation combined with liquid-liquid extraction. This developed method only requires 50 μL of plasma for the analysis. The chromatographic separation was performed with a Waters symmetry, C18 , 4.6 × 150 mm, 5 μm column using formic acid, water and acetonitrile as solvent delivered at a 0.7 mL/min flow rate. The total run time of the method was 3 min. The method was validated according to regulatory guidance in terms of specificity, selectivity, linearity, matrix effect, recovery and stability. Optimized Q1/Q3 mass transitions for armodafinil and armodafinil d-10 were 274.1/167.2 (m/z) and 284.4/177.4 (m/z) respectively. The method showed linearity within the tested concentration range of 10-10,000 ng/mL. The method was successfully applied to quantify armodafinil concentrations after single oral administration of a 250 mg tablet in a clinical study conducted in healthy volunteers. Significant advantages of this method are minimal sample volume, short run time and a lower LLOQ.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
09:09Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation