Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
Office blood pressure measurement in the 21st century
Martin G Myers1, Roland Asmar2, Jan A Staessen3,4
1Division of Cardiology, Schulich Heart Program, Sunnybrook Health Sciences Centre and Department of Medicine, University of Toronto, Toronto, ON, Canada.
Abstract:
Measurement of blood pressure (BP) using the auscultatory method must follow specific rules and conditions to be reliable. Nonetheless, these requirements are often not followed in clinical practice, resulting in inaccurate BP readings. Simply replacing manual sphygmomanometers with an oscillometric device may still produce readings that are associated with a white coat effect. These limitations can be overcome by using an oscillometric sphygmomanometer that automatically records multiple readings with the patient resting quietly and alone, called automated office (AO)BP. AOBP produces office readings with a reduced white coat effect, which are also similar to the awake ambulatory BP. There is also evidence that AOBP is a better predictor of target organ damage than attended office BP. Furthermore, clinical outcome data support AOBP as having both a similar diagnostic threshold as awake ambulatory BP and a lower treatment target. Using AOBP in clinical practice simplifies recording office BP by not requiring an additional period of rest before activation of the device and by not having staff present during the actual measurements. Recent studies have reported that automatic BP measurements taken by staff in research studies with close adherence to guidelines using AOBP devices may produce similar readings to AOBP. Further research is needed to determine the best method for recording BP at systolic targets < 130 mm Hg and the relationship of office BP to ambulatory BP and home BP.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer