Related Experiment Video
Updated: Feb 7, 2026

Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
The quest for accuracy of blood pressure measuring devices
Eoin O'Brien1, George S Stergiou2, Martin J Turner3,4
1The Conway Institute, University College Dublin, Dublin, Ireland.
Abstract:
The accuracy of blood pressure (BP) measuring devices is fundamental to good practice and scientific research. International guidelines on BP measurement are provided for clinicians who diagnose and treat patients with hypertension, clinical researchers who conduct trials on the efficacy of BP lowering drugs and interventional strategies, epidemiologists who conduct population surveys to determine the demographic consequences of hypertension on society, and researchers who perform meta-analyses on published research to further influence the practice of medicine and the provision of resources. Although the outcomes of the endeavors of all these groups are dependent on the accuracy of BP measurements, the equipment is often of doubtful accuracy and the methodology of measurement is often poorly described and frequently not standardized. Thus, the fundamental element of hypertension evaluation has been largely ignored by both clinical practitioners and scientific researchers. Here, the authors briefly review the development of efforts to improve and validate the accuracy of BP measuring devices and highlight the deficiencies that persist. We conclude that, to protect the public from the serious consequences of inaccurate BP measurements, the following steps are required: (1) regulatory requirement for mandatory independent validation of all BP measuring devices using a universal protocol; (2) accreditation of laboratories for the performance of BP device validations; (3) online evaluation of validation studies with detection of protocol violations prior to publication of results; and (4) establishment of an independent scientific forum for the listing of accurate BP measuring devices.
Related Concept Videos
Measurement of Blood Pressure
Uncertainty in Measurement: Accuracy and Precision
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...