Related Experiment Video
Updated: Feb 7, 2026

Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
Assessment of Pronator Quadratus Repair Integrity Using Dynamic Ultrasonography Following Volar Plate Fixation for
Richard M Hinds1, Nicole Montero-Lopez1, Kenneth Brock2
1NYU Langone Orthopedic Hospital, New York, USA.
Pronator quadratus (PQ) repair after volar plate fixation (VPF) for distal radius fractures (DRF) shows high durability. Dynamic ultrasonography confirmed intact PQ repairs in all patients, with similar functional outcomes regardless of volar plate coverage.
Area of Science:
- Orthopedic Surgery
- Musculoskeletal Imaging
- Reconstructive Surgery
Background:
- Previous studies indicated potential failure of pronator quadratus (PQ) repair post-volar plate fixation (VPF) for distal radius fractures (DRF).
- Assessing the integrity of PQ repair is crucial for understanding functional outcomes after DRF treatment.
Purpose of the Study:
- To evaluate the integrity of the pronator quadratus (PQ) repair following volar plate fixation (VPF) of distal radius fractures (DRF).
- To assess the relationship between PQ repair integrity, volar plate coverage, and functional outcomes using dynamic musculoskeletal ultrasonography.
Main Methods:
- Twenty adult patients undergoing VPF of DRF with PQ repair were evaluated using bilateral dynamic wrist ultrasonography.
- Assessments included PQ repair integrity, wrist range of motion (ROM), strength, and functional outcome scores at a minimum 3-month follow-up.
Main Results:
- All patients demonstrated intact pronator quadratus (PQ) repairs at a mean follow-up of 9 months.
- Complete coverage of the volar plate by the PQ occurred in 55% of patients, associated with a larger PQ size (P = .026).
- No significant differences in ROM, strength, or functional outcomes were observed between wrists with complete or incomplete volar plate coverage by the PQ.
Conclusions:
- Pronator quadratus (PQ) repair exhibits significant durability after volar plate fixation (VPF) for distal radius fractures (DRF).
- Functional outcomes, including wrist range of motion and strength, are comparable whether the volar plate is fully or partially covered by the repaired PQ.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Radius of Gyration of an Area
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Mismatch Repair
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Schwarzschild Radius and Event Horizon
The minimum speed required to launch a projectile from the surface of an object to which it is gravitationally bound so that it eventually escapes the object’s gravitational field is called the escape velocity. The escape velocity is independent of the mass of the object. Merging the idea of escape...