Related Experiment Video
Updated: Feb 7, 2026

Personalized 3D-printed Headgear for Multi-electrode Transcranial Electrical Stimulation
Published on: September 9, 2025
Exterior-electrode electrically driven microconcentrator
Chia-Chun Hsu1, Yan-Chang Lee1, Wen-Hsin Hsieh1
1Department of Mechanical Engineering and Advanced Institute of Manufacturing with High-tech Innovations, National Chung Cheng University, Chia-Yi, Taiwan, Republic of China.
Abstract:
This study uses negative dielectrophoresis and AC electroosmosis as a driving mechanism and presents an electrically driven microconcentrator that concentrates the sample in the region exterior to the electrodes (termed as exterior-electrode electrically driven microconcentrator in this paper). The proposed microconcentrator uses a 3-D face-to-face electrode pair; the top electrode is a relatively large planar electrode, and the bottom electrode is formed with three to six long and thin electrodes connected into an open ring. The sample is brought to the vicinity of the open electrode at the bottom by electroosmotic flow; then, negative dielectrophoresis is used to push the sample away from the electrode and concentrate it in the region surrounded by the open ring electrode. Concentration using an exterior-electrode electrically driven microconcentrator offers promise for convenient use in conjunction with relevant detection systems. The results indicate that for the proposed exterior-electrode electrically driven microconcentrator, the optimal frequency is 100 kHz and the optimal voltage is 13 Vp-p . The corner concentration process at the corners of the bottom open electrodes enables the multi-corner electrodes to exhibit better concentration results than that exhibited by semicircular-shaped electrodes. The concentration performance is most favorable when the shape of the open electrode at the bottom is a five-vertex electrode, enabling a concentration enhancement factor of 55 times for a latex particle solution and 11 times for E. coli. The experimental results also demonstrate that the concentration phenomenon in this study is not induced by non-specific adsorption and can be repeated multiple times.
More Related Videos
10:51Fabrication and Validation of an Organ-on-chip System with Integrated Electrodes to Directly Quantify Transendothelial Electrical Resistance
Published on: September 26, 2017
09:36In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy
Published on: September 12, 2018
Related Concept Videos
Standard Electrode Potentials
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...
Finding Electric Potential From Electric Field
Determining Electric Field From Electric Potential
In general, regardless of whether the electric field is uniform, it points in the direction of decreasing potential because the force on a positive...
Electric Potential Energy in a Uniform Electric Field