Delivery of sevoflurane using a neonatal ventilator
Richard J Burstal1, Steven J Threlfo1
1Department of Anaesthesia, John Hunter Hospital, Newcastle, New South Wales, Australia.
Background:
Most anesthetic ventilators are designed to cope with a wide range of patient sizes and may lack precision at the lowest end of the minute volume scale. Neonatal intensive care ventilators on the other hand are designed specifically for this patient group, but are not able to deliver volatile anesthesia.
Aims:
We aimed to adapt the neonatal ventilator currently in use in our institution to deliver sevoflurane by incorporating a vaporizer and a scavenging system.
Methods:
We used a Diamedica draw-over vaporizer incorporated into the ventilator circuit and a custom designed open interface scavenging system. A number of safety measures are described to ensure that this equipment is correctly inserted into the circuit.
Results:
Bench testing revealed that the vaporizer output is linear and stable within the circuit flow range 4-8 L/min in all modes except high frequency oscillation where concentrations are not predictable. The scavenging system was found to be effective and did not affect volumes, pressures or waveforms when ventilating a test lung over a wide range of flows and pressures. This remained the case over the full range of scavenger flow adjustment.
Conclusion:
The addition of a Diamedica vaporizer to a Fabian neonatal ventilator was shown in bench testing to provide stable, linear vapor concentrations without compromise of ventilator function. The system should not be used in high frequency oscillation mode because concentrations will exceed those expected and will not maintain a linear relationship with the vaporizer setting.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation I: Indication and Settings