Wei Ren Daniel Seng1, Siaw Meng Chou2, Shiblee S Siddiqui1
1Department of Orthopaedic Surgery, Tan Tock Seng Hospital, National Health Group, Nanyang, Singapore.
Study Design:
An experimental laboratory-based biomechanical study.
Objective:
The objective of this study was to evaluate, in a synthetic bone model, the difference in primary and revision pull-out strength using pedicle screws of different thread designs.
Summary Of Background Data:
Over the past few decades, there has been a growing interest in optimizing the screw pull-out strength using various screw designs (single-thread, mixed-thread, dual-thread). Although primary pull-out strength has been studied previously, little is known about revision pull-out strength of different pedicle screws.
Methods:
The pull-out strengths of three different pedicle screw designs (single-thread, mixed-thread, dual-thread) were tested in standardized polyurethane foam in three sequences. Sequence 1: A 6.5 mm screw was inserted into the foam block and the primary pull-out strength measured. Sequence 2: A 6.5 mm screw was inserted, removed, and then reinserted into the same foam block. The revision pull-out strength was then measured. Sequence 3: A 6.5 mm screw was inserted, removed and a 7.5-mm screw of the same thread design was reinserted. The revision pull-out strength was then measured.
Results:
The primary pull-out strength was similar across screw designs, although dual-thread screws showed higher primary pull-out strength (2628.8 N) compared to single-thread screws (2184.4 N, P < 0.05). For revision pull-out strength, the mixed-thread screws had significant reduction in revision pull-out strength of 18.6% (1890.2 N, P = 0.0173). Revision with a larger diameter screw improved the pull-out strength back to baseline. Single and dual-thread screws showed no significant reduction in revision pull-out strength.
Conclusion:
The dual-threaded screws provided the strongest primary pull-out strength for spinal fixation. The mixed-thread screws, however, had the poorest revision pull-out strength, decreasing by 18.6% compared to other screw designs. In cases in which mixed-threaded screws have to be revised (at the index or revision surgery), surgeons should consider the use of larger diameter screws to improve the pull-out strength.
Level Of Evidence:
5.
Related Concept Videos
Study Designs in Epidemiology
Observational studies are those where the researcher does not intervene but rather observes natural variations. They include cross-sectional, cohort, and...
Study Design in Statistics
Does aspirin reduce the risk of heart attacks? Is one brand of fertilizer more effective at growing roses than another? Is fatigue as dangerous to a driver as the influence of alcohol? Questions like these are answered using randomized experiments with proper...
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...