Related Experiment Video
Updated: Jul 29, 2026

Fluorescent Paper Strips for the Detection of Diesel Adulteration with Smartphone Read-out
Published on: November 9, 2018
A paper-based optical probe for chromium by using gold nanoparticles modified with 2,2'-thiodiacetic acid and
Shadab Faham1, Gholamreza Khayatian2, Hamed Golmohammadi3
1Department of Chemistry, Faculty of Science, University of Kurdistan, P.O. Box 416, Sanandaj, 66177-15175, Iran.
Abstract:
A paper based analytical device is presented for the determination of Cr(III) and Cr(VI) using gold nanoparticles (AuNPs) modified with 2,2'-thiodiacetic acid. The modified AuNPs were characterized using UV-Vis spectrophotometry, Fourier transform infrared, dynamic light scattering, zeta potential, energy dispersive spectroscopy and transmission electron microscopy. Cr(III) ions induce the aggregation of the modified AuNPs, and the color of the nanoprobe changes from red to blue. This can be detected visually, or by colorimetry, or with a camera. No interference is observed in the presence of 19 other cations and anions. Cr(VI) (chromate) can be determined by after reduction to Cr(III) by using ascorbic acid and then quantified total Cr(III). The concentration of Cr(VI) is obtained by subtracting the concentration of Cr(III) from that of total chromium. Under optimal conditions, the ratio of the absorbances measured at 670 (blue) and 522 (red) increases linearly in the 1.0 nM to 22.1 μM chromium concentration range, with 0.66 nM (0.034 ppb) limit of detection (LOD) in solution. In case of the paper device, the linear range extends from 1.0 nM to 0.1 mM, and the LOD is 0.64 nM (0.033 ppb). The method was applied to the determination of chromium in spiked water, urine and dilutes human plasma, and results were confirmed by GF-AAS analysis. This method is highly selective, fast and portable, requires minimum volume of reagents and samples and no washing steps. Graphical abstract A paper based analytical device is presented for determination of Cr(III) and Cr(VI) using gold nanoparticles modified with 2,2'-thiodiacetic acid. In paper optical probe, linear range and limit of detection are 1.0 nM to 0.1 mM and 0.64 nM, respectively. The method was applied to the determination of total chromium in spiked water, urine and dilutes human plasma, and results were confirmed by GF-AAS analysis.
More Related Videos
06:00Portable Paper-Based Immunoassay Combined with Smartphone Application for Colorimetric and Quantitative Detection of Dengue NS1 Antigen
Published on: January 26, 2024
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025