Related Experiment Video
Updated: Feb 7, 2026

Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
Minimal versus obligatory dissection of the diaphragmatic hiatus during magnetic sphincter augmentation surgery
James M Tatum1, Evan Alicuben1, Nikolai Bildzukewicz1
1Division of Upper GI and General Surgery, Department of Surgery, Keck School of Medicine of the University of Southern California, 1450 San Pablo Street, Healthcare Consultation Center 4, Suite 6200, Los Angeles, CA, 90033, USA.
Background:
The magnetic sphincter augmentation (MSA) device was initially implanted with minimal hiatal dissection (MHD) at the diaphragmatic hiatus. Due to concern of possible MSA device dysfunction if herniated into an occult or small hiatal hernia, and increased understanding to the role of defective crura in reflux disease, the operative procedure was changed to planned obligatory dissection (OD) of the hiatus at the time of all implantations.
Methods:
Between December 2012 and September 2016, 182 patients underwent MSA implant at a single medical center and have complete records available for review through September 2017. The MHD dissection period extended from December 2012 to September 2015, from September 2015 to 2016 all patients underwent OD.
Results:
MHD occurred 53% (96/182) versus OD in 47% (86/182), mean follow-up time in days for MHD and OD was 554 (SD 427) versus 374 (298) days. Intraoperative measurement of hernia size for the MHD versus OD was 0.77 (1.1) versus 3.95 (2.4) cm, p < 0.001. At first visit follow-up, there was no difference in any dysphagia (p = 0.11). Recurrent GERD (defined as resumption of PPI after successful initial post-operative wean) was less frequent after OD than after MHD, 3.6 versus 16.3%, p = 0.006. Delayed onset dysphagia was 1.2% in the OD group versus 8.6% in the MHD group, p = 0.04. Recurrent hiatal hernia of 2 cm or greater occurred in 0.0% of the OD and 11.5% of the MHD, p = 0.03. Repeat surgery for hiatal hernia repair has occurred in 0% of the OD and 6.6% of the MHD, p = 0.02.
Conclusion:
OD of the hiatus with crural closure resulted in less recurrence of reflux symptoms and hiatal hernia, despite an increased proportion of patients with larger hiatal hernia and more complex anatomic disease at the time of operation.
Related Concept Videos
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Magnetism
An individual magnetic pole cannot be isolated. No matter how small, every piece of a magnet contains a north pole and a south...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Magnetic Flux
Suppose a surface is divided into elements of area dA. For each element, the component of the magnetic field that is normal to the...
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Magnetic Declination

