Background:
In acute stroke, the magnetic resonance (MR) imaging-based mismatch concept is used to select patients with tissue at risk of infarction for reperfusion therapies. There is however a controversy if non-deconvolved or deconvolved perfusion weighted (PW) parameter maps perform better in tissue at risk prediction and which parameters and thresholds should be used to guide treatment decisions.
Methods:
In a group of 22 acute stroke patients with consecutive MR and quantitative positron emission tomography (PET) imaging, non-deconvolved parameters were validated with the gold standard for penumbral-flow (PF) detection 15O-water PET. Performance of PW parameters was assessed by a receiver operating characteristic curve analysis to identify the accuracy of each PWI map to detect the -upper PF threshold as defined by PET cerebral blood flow <20 mL/100 g/min.
Results:
Among normalized non-deconvolved parameters, PW-first moment without delay correction (FM without DC) > 3.6 s (area under the curve [AUC] = 0.89, interquartile range [IQR] 0.85-0.94), PW-maximum of the concentration curve (Cmax) < 0.66 (AUC = 0.92, IQR 0.84-0.96) and PW-time to peak (TTP) > 4.0 s (AUC = 0.92, IQR 0.87-0.94) perform significantly better than other non-deconvolved parameters to detect the PF threshold as defined by PET.
Conclusions:
Non-deconvolved parameters FM without DC, Cmax and TTP are an observer-independent alternative to established deconvolved parameters (e.g., Tmax) to guide treatment decisions in acute stroke.
More Related Videos
09:5718F-Labeling of Radiotracers Functionalized with a Silicon Fluoride Acceptor SiFA for Positron Emission Tomography
Published on: January 11, 2020
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Reliability and Validity
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Mismatch Repair
Mismatch Repair
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...