Related Experiment Video
Updated: Feb 7, 2026

Multimodality Diagnosis of Mesenteric Ischemia
Published on: July 21, 2023
4D flow MRI for the analysis of celiac trunk and mesenteric artery stenoses
Florian Siedek1, Daniel Giese1, Kilian Weiss2
1Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany.
Purpose:
This study aims to assess the feasibility of 4D flow MRI measurements in complex vascular territories; namely, the celiac artery (CA) and superior mesenteric artery (SMA).
Materials And Methods:
In this prospective study, 22 healthy volunteers and 10 patients were scanned at 3 T. Blood flow parameters were compared between healthy volunteers and patients with stenosis of the CA and/or SMA as a function of stenosis grade characterized by prior contrast-enhanced computed tomography (CE-CT). The 4D flow MRI acquisition covered the CA, SMA and adjusting parts of the abdominal aorta (AO). Measurements of velocity- (peak velocity [PV], average velocity [AV]) and volume-related parameters (peak flow [PF], stroke volume [SV]) were conducted. Further, stenosis grade and wall shear stress in the CA, SMA and AO were evaluated.
Results:
In patients, prior evaluation by CE-CT revealed 11 low- and 5 mid-grade stenoses of the CA and/or SMA. PV and AV were significantly higher in patients than in healthy volunteers [PV: p < 0.0001; AV: p = 0.03, p < 0.001]. PF and SV did not differ significantly between healthy volunteers and patients; however, a trend towards lower PF and SV could be detected in patients with mid-grade stenoses. Comparison of 4D flow MRI with CE-CT revealed a strong positive correlation in estimated degree of stenosis (CA: r = 0.86, SMA: r = 0.98). Patients with mid-grade stenoses had a significantly higher average WSS magnitude (AWM) than healthy volunteers (p = 0.02).
Conclusion:
This feasibility study suggests that 4D flow MRI is a viable technique for the evaluation of complex flow characteristics in small vessels such as the CA and SMA. 4D flow MRI approves comparable to the morphologic assessment of complex vascular territories using CE-CT but, in addition, offers the functional evaluation of flow parameters that goes beyond the morphology.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Arteries of Lower Limbs
Arteries and Arterioles
Gene Flow
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Arteries of the Upper Limbs