Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Graded Potential01:19

Graded Potential

7.1K
Graded potentials are localized fluctuations in the cell membrane's electrical charge, commonly found in the dendrites of neurons. The magnitude of these potential changes depends on the strength of the initiating stimulus. In a membrane at its resting potential, a graded potential signifies a voltage shift either above -70 mV or below -70 mV.
Graded potentials fall into two categories: depolarizing and hyperpolarizing. Depolarizing graded potentials typically occur when sodium (Na+) or...
7.1K
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

1.6K
There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
1.6K
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

2.0K
Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
2.0K
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

1.2K
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
1.2K
Types of Aggregate Grading01:15

Types of Aggregate Grading

1.5K
Aggregate grading is crucial in economically obtaining a concrete mix with adequate strength, reasonable workability, and minimal segregation. There are four types of aggregate gradation: well-graded, uniformly (or one-sized) graded, gap-graded, and open-graded.
Well-graded aggregates include a complete range of necessary size fractions that fit together to create a dense matrix with minimal voids, represented by a smooth, continuous gradation curve. This type of grading ensures good...
1.5K
Cable Subjected to Its Own Weight01:13

Cable Subjected to Its Own Weight

800
Overhead power transmission lines rely on cables to carry electricity across large distances. To ensure the stability and functionality of these lines, it is crucial to understand the shape and tension experienced by the cables under the influence of their weight.
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
800

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Pathologic complete response and survival in early-stage HER2-positive breast cancer patients treated with or without anthracyclines.

Ecancermedicalscience·2026
Same author

Hetairos is a histology-based artificial intelligence model for predicting central nervous system tumor methylation subtypes.

Nature cancer·2026
Same author

Clinicopathological analysis of actinic keratosis affecting the eyelid.

Canadian journal of ophthalmology. Journal canadien d'ophtalmologie·2026
Same author

ThyroidPrint: Thyroid Genetic Classifier Long-Term Follow-Up of Benign Called Lesions.

Clinical endocrinology·2026
Same author

Differential protective effects of blue light (BL)-exposed retinal pigment epithelial cells by selective BL-filtering lenses.

Experimental eye research·2026
Same author

Six-year trends in amblyopia burden and clinic workload among Inuit children in Nunavik: a population-based cohort study.

Canadian journal of ophthalmology. Journal canadien d'ophtalmologie·2026

Related Experiment Video

Updated: Feb 7, 2026

Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
04:59

Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation

Published on: July 7, 2023

3.0K

Removing Subjective Post-Mortem Grading from Posterior Capsular Opacification: A New Automated Detector Opacification

Christina Mastromonaco1, Matthew Balazsi2, Pablo Zoroquiain1

  • 1a Ocular Pathology Laboratory- Department of Pathology , The MUHC-McGill University , Montreal , Quebec , Canada.

Current Eye Research
|July 17, 2018
PubMed
Summary

A new software for grading posterior capsular opacification (PCO) after cataract surgery shows high reproducibility and objectivity. This automated system offers a reliable alternative to subjective methods, improving PCO assessment accuracy.

Keywords:
Posterior capsular opacificationintraocular lensobjective softwarepathologypost-mortem eyes

More Related Videos

A Protocol for Rapid Post-mortem Cell Culture of Diffuse Intrinsic Pontine Glioma DIPG
08:46

A Protocol for Rapid Post-mortem Cell Culture of Diffuse Intrinsic Pontine Glioma DIPG

Published on: March 7, 2017

17.5K
Isolation of Cardiomyocyte Nuclei from Post-mortem Tissue
10:12

Isolation of Cardiomyocyte Nuclei from Post-mortem Tissue

Published on: July 10, 2012

17.6K

Related Experiment Videos

Last Updated: Feb 7, 2026

Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
04:59

Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation

Published on: July 7, 2023

3.0K
A Protocol for Rapid Post-mortem Cell Culture of Diffuse Intrinsic Pontine Glioma DIPG
08:46

A Protocol for Rapid Post-mortem Cell Culture of Diffuse Intrinsic Pontine Glioma DIPG

Published on: March 7, 2017

17.5K
Isolation of Cardiomyocyte Nuclei from Post-mortem Tissue
10:12

Isolation of Cardiomyocyte Nuclei from Post-mortem Tissue

Published on: July 10, 2012

17.6K

Area of Science:

  • Ophthalmology
  • Medical Imaging
  • Biomedical Engineering

Background:

  • Posterior capsular opacification (PCO) is the most common complication after cataract surgery.
  • Current PCO grading methods are subjective and prone to errors, necessitating objective and reproducible assessment tools.

Purpose of the Study:

  • To evaluate the reproducibility and objectivity of a novel, custom-designed automated software for PCO detection.
  • To compare the software's performance against traditional subjective grading methods.

Main Methods:

  • 165 eyes with intraocular lenses underwent imaging using the Miyake Apple view (MAV) and capsular bag (CB) methods.
  • Ophthalmologists graded PCO area and intensity (0-4 scale); a custom software was developed for automated PCO detection.
  • Correlation analysis was performed between subjective grading, software output, and inter-observer agreement.

Main Results:

  • Inter-observer agreement for subjective grading ranged from fair to good.
  • The software demonstrated very good correlation with subjective intensity grading (r=0.85) and good correlation with area grading (r=0.61).
  • The capsular bag (CB) view provided better visualization for PCO quantification compared to the Miyake Apple view (MAV).

Conclusions:

  • The developed software is a reliable and reproducible system for PCO assessment, correlating well with existing scoring methods.
  • Automated PCO detection software reduces subjectivity and enhances the accuracy of grading this common post-cataract surgery complication.
  • The capsular bag (CB) imaging technique is advantageous for direct visualization, avoiding interference from overlapping structures.