Related Experiment Video
Updated: Feb 7, 2026

Application of Deep Learning-Based Medical Image Segmentation via Orbital Computed Tomography
Published on: November 30, 2022
Value of computed tomography in calculating prostate volume when transrectal ultrasonography is not applicable
Young Ju Lee1, Sung Han Kim2, Hwanik Kim3
1Department of Urology, Seoul National University Bundang Hospital, Seongnam, Republic of Korea.
Objective:
The aim of this study was to evaluate the value of computed tomography (CT) in determining total prostate volume (TPV), as an alternative to transrectal ultrasonography (TRUS) when TRUS is not available.
Methods:
The patient cohort included patients who underwent both CT and TRUS within a 3-month interval from January 2012 to December 2013 at a single institution. In all, 67 non-contrast and 217 contrast-enhanced CT images were reviewed twice by 3 independent observers 2 months after the initial evaluation. Prostate length and width were measured on axial images and height was measured on sagittal images. To compare differences between CT and TRUS in TPV estimation, the CT/TRUS ratio of TPV was calculated and a Bland-Altman plot was constructed. Inter- and intraobserver variabilities and the effect of contrast enhancement were also evaluated statistically.
Results:
The mean (± SD) age of patients was 64.5 ±10.8 years and the mean time interval between CT and TRUS was 16.3 ± 22.6 days. The mean TRUS-measured TPV was 44.7 ± 24.9 mL and the mean CT/TRUS TPV ratio was 0.80 ± 0.20, indicating that TPV estimated by CT is 20% lower than that determined by TRUS, regardless of contrast enhancement (P > .05). The mean difference in TPV between TRUS and CT was 11.3 ± 14.3 mL, with differences of 1.7, 9.9, and 32.9 mL for prostate volumes of ≤30, >30-60, and >60 mL, respectively. Interobserver variability was excellent (r > 0.9), whereas intraobserver variability was very good (r > 0.7).
Conclusion:
CT is a reliable method for prostate volume measurement and is well correlated with TRUS. Although CT estimates of TPV are 20% lower than those obtained using TRUS, CT can be used as an alternative to TRUS when TRUS is not available.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Calculation of Volume of Solids by Integration
Imaging Studies III: Computed Tomography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume
Calculating pH Changes in a Buffer Solution