Related Experiment Video
Updated: Feb 7, 2026

Serum and Plasma Copy Number Detection Using Real-time PCR
Published on: December 15, 2017
Near Real-Time Detection of E. coli in Reclaimed Water
Samendra Sherchan1,2, Syreeta Miles3,4, Luisa Ikner5
1Department of Global Environmental Health Sciences, Tulane University, 1440 Canal St, New Orleans, LA 70112, USA. sshercha@tulane.edu.
Abstract:
Advanced treatment of reclaimed water prior to potable reuse normally results in the inactivation of bacterial populations, however, incremental treatment failure can result in bacteria, including pathogens, remaining viable. Therefore, potential microorganisms need to be detected in real-time to preclude potential adverse human health effects. Real-time detection of microbes presents unique problems which are dependent on the water quality of the test water, including parameters such as particulate content and turbidity, and natural organic matter content. In addition, microbes are unusual in that: (i) viability and culturability are not always synonymous; (ii) viability in water can be reduced by osmotic stress; and (iii) bacteria can invoke repair mechanisms in response to UV disinfection resulting in regrowth of bacterial populations. All these issues related to bacteria affect the efficacy of real-time detection for bacteria. Here we evaluate three different sensors suitable for specific water qualities. The sensor A is an on-line, real-time sensor that allows for the continuous monitoring of particulates (including microbial contaminants) using multi-angle-light scattering (MALS) technology. The sensor B is a microbial detection system that uses optical technique, Mie light scattering, for particle sizing and fluorescence emission for viable bacteria detection. The last sensor C was based on adenosine triphosphate (ATP) production. E. coli was used a model organism and out of all tested sensors, we found the sensor C to be the most accurate. It has a great potential as a surrogate parameter for microbial loads in test waters and be useful for process control in treatment trains.
More Related Videos
12:50Colorimetric Paper-based Detection of Escherichia coli, Salmonella spp., and Listeria monocytogenes from Large Volumes of Agricultural Water
Published on: June 9, 2014
11:00Real-Time Quantification of Reactive Oxygen Species in Neutrophils Infected with Meningitic Escherichia Coli
Published on: April 20, 2021
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
The Water Cycle
Chemotaxis in E. coli
Water and Mineral Acquisition
Quality of Water