Noninvasive method for measurement of cerebral blood flow using O-15 water PET/MRI with ASL correlation
Hidehiko Okazawa1, Yoshifumi Higashino2, Tetsuya Tsujikawa1
1Biomedical Imaging Research Center, University of Fukui, 23-3, Matsuoka-Shimaizuki, Eiheiji-cho, Fukui, 910-1193, Japan.
Purpose:
A noninvasive image derived input function (IDIF) method was applied to estimate arterial input function from brain H215O-PET/MRI images for the measurement of cerebral blood flow (CBF) because of difficulty in arterial blood sampling during PET/MRI scans. To evaluate accuracy and reproducibility of radioactivity in the internal carotid arteries (ICA) for the IDIF method, a new phantom using a skull bone was applied in the cross-calibration process between the scanner and a gamma-well counter.
Methods:
Eleven healthy volunteers (9 males, 43.9 ± 10.9y) underwent PET/MRI studies with a 3-min H215O-PET and several MRI scans including arterial spin labeling (ASL) perfusion MRI. PET images were reconstructed as dynamic data using two sets of reconstruction parameters, which were determined by basic assessment of radioactivity concentration reproducibility in the tubes of the phantom. The IDIF method extracted the time-activity curves of the ICA from several image slices in the PET data. CBF images were calculated using the autoradiographic (ARG) method and a one-tissue compartment model (1-TCM).
Results:
The global means of CBF from the ARG, 1-TCM, and ASL-MRI were 44.8 ± 4.3, 47.9 ± 5.9 and 57.9 ± 8.6 (mL/min/100 g), respectively. CBF from ASL-MRI was significantly greater compared with CBF from H215O-PET (P < 0.001). However, these CBF values were significantly correlated with each other in the scatter plots (P < 0.05).
Conclusions:
Noninvasive measurement of CBF using H215O-PET/MRI and IDIF with the cross-calibration method with a skull phantom experiment provided reasonable quantitative values. The IDIF method allowed reliable estimation of arterial radioactivity concentration, which is useful for clinical application. The ASL-MRI perfusion image from the simultaneous acquisition tended to overestimate CBF.
Related Concept Videos
Blood Flow
Correlations
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Applications of Integration to Find Blood Flow
Other Nuclides: 31P, 19F, 15N NMR
While fluorine-19 and phosphorous-31 have high natural abundances (100%) and positive gyromagnetic ratios, nitrogen-15 has a low natural abundance and a negative gyromagnetic ratio. However, nitrogen-15 is still preferred over nitrogen-14 (which has a...