Bone marrow edema in traumatic vertebral compression fractures: Diagnostic accuracy of dual-layer detector CT using
Victor Neuhaus1, Simon Lennartz1, Nuran Abdullayev1
1Department of Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany.
Purpose:
To evaluate calcium suppressed images (CaSupp) in dual-layer detector computed tomography (DLCT) for the detection of bone marrow edema (BME) in vertebral fractures.
Materials And Methods:
The retrospective study was approved by the institutional review board. 34 patients with synchronous DLCT and MRI, who were diagnosed with one or more acute vertebral fractures, were included. MRI were systematically analyzed as reference standard. Two blinded and independent readers evaluated CaSupp for vertebral BME. Additionally, both readers determined the optimal calcium suppression indices (CaSupp-I) for visualization of BME in consensus and correlated the CaSupp-I with parallel measurement of trabecular density as surrogate parameter for bone mineral density. ROI-based measurements of the contrast-to-noise ratios (CNR) were also conducted. Interrater agreement was determined by kappa-statistics. CNR were analyzed using Wilcoxon signed rank test.
Results:
Fifty-seven acute fractured vertebrae out of 383 vertebrae (14.9%) were found. CaSupp yielded an average sensitivity of 87% and specificity of 99%, a positive predictive value of 95%, a negative predictive value of 98% and an accuracy of 97% for the detection of fracture-associated edema. Interrater agreement was excellent (kappa 0.91). Increase in CNR of BME correlated with increasing CaSupp-I. Edema adjacent to the cortical endplates was better visualized using CaSupp-I of 70 and 80, while extensive edema was better visualized using a CaSupp-I of 90 and 100 (chi2 < 0.0001). No correlation between optimal CaSupp-I and trabecular density was found (p > 0.2).
Conclusion:
CaSupp reconstructed from DLCT enable visualization and detection of BME in traumatic fractured vertebrae with high diagnostic accuracy using CaSupp-I of 70-100.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bone Marrow Sampling and Transplants
The transplant begins with high doses of chemotherapy and radiation treatment, which aim to destroy...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Improving Translational Accuracy