Related Experiment Video
Updated: Feb 7, 2026

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Optical Frequency Domain Imaging Evaluation of Progressive Carotid Plaque and In-Stent Restenosis Lesion with
Masatomo Miura1, Kiyofumi Yamada2, Seigo Shindo3
1Department of Neurosurgery, Hyogo College of Medicine, Hyogo, Japan; Department of Neurology, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan.
Background:
Neovascularization (NV) plays an important role in plaque progression and plaque vulnerability. However, visualization of NV is difficult using standard imaging tools. Recently, optical frequency domain imaging (OFDI) has provided images of intraplaque microstructure that could not be visualized by previous imaging modalities. Here we report a rare case of NV in the carotid plaque detected both before carotid artery stenting (CAS) and in an in-stent restenotic lesion using OFDI.
Case Description:
A 71-year-old man with asymptomatic severe left carotid artery stenosis was scheduled for CAS. The degree of stenosis had progressed during short-term follow-up. Preoperative magnetic resonance imaging suggested vulnerable plaque. We performed OFDI to evaluate plaque morphology before and after the CAS procedure. Before CAS, OFDI revealed multiple NVs in the carotid plaque, localized around the most stenotic lesion. After CAS, OFDI showed good apposition of the stent to the vascular wall. At 5 months after CAS, in-stent restenosis was detected, which was treated by CAS. Before CAS of the restenotic lesion, OFDI revealed multiple NVs in the restenotic lesion inside the stent struts. After stenting, no ischemic lesions were detected, and restenosis did not occur again over the 1-year follow-up period.
Conclusions:
In carotid artery plaque, NV might correlate with plaque progression and in-stent restenosis. OFDI enables advanced evaluation of NVs in the carotid artery plaque.
More Related Videos
Related Concept Videos
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Conservation of Protein Domains Over Different Proteins
A limited set of protein domains often duplicate and recombine during evolution. These domains can be organized in different combinations to...

