Related Experiment Video
Updated: Feb 7, 2026

Evaluation of the Cognitive Performance of Hypertensive Patients with Silent Cerebrovascular Lesions
Published on: April 23, 2021
Silent cerebral events/lesions after second-generation cryoballoon ablation: How can we reduce the risk of silent
Shinsuke Miyazaki1, Takatsugu Kajiyama2, Kazuya Yamao2
1Department of Cardiovascular medicine, Fukui University, Fukui, Japan.
Background:
Atrial fibrillation (AF) ablation is associated with a substantial risk of silent cerebral events/lesions (SCEs/SCLs) detected on magnetic resonance imaging (MRI).
Objective:
The purpose of this study was to investigate the factors associated with the incidence of SCEs/SCLs during second-generation cryoballoon ablation.
Methods:
Two hundred fifty-six AF patients underwent brain MRI 1 day after pulmonary vein (PV) isolation using second-generation cryoballoons with a single 28-mm balloon and short freeze strategy.
Results:
Overall, 991 of 1016 PVs (97.5%) were successfully isolated by 4.9 ± 1.3 cryoballoon applications per patient, and 25 PVs required touch-up radiofrequency ablation. The total procedure time was 72.7 ± 26.1 minutes. SCEs and SCLs were detected in 68 (26.5%) and 27 (10.5%) patients, respectively. None of the patients reported any neurologic symptoms. Reinsertion of once withdrawn cryoballoons and subsequent applications significantly increased the incidence of SCEs (odds ratio [OR] 2.057; 95% confidential interval [CI] 1.051-4.028; P = .035), and additional left atrial mapping with a multielectrode catheter significantly increased the incidence of SCLs (OR 3.317; 95% CI 1.365-8.056; P = .008). Transient coronary air embolisms were significantly associated with the incidence of SCLs (OR 3.447; 95% CI 1.015-11.702; P = 0.047). On the contrary, an uninterrupted anticoagulation regimen, use of radiofrequency deliveries for transseptal access, cryoballoon air removal with extracorporeal balloon inflations, strength of the MRI magnet, internal electrical cardioversion, and touch-up ablation were not associated with the incidence of SCEs/SCLs.
Conclusion:
A significant number of SCE/SCL occurrences was observed after second-generation cryoballoon ablation procedures. These results suggest that air embolisms are the main mechanism of SCEs/SCLs, and the injected air volume might determine the lesion type.
More Related Videos
Related Concept Videos
Relative Risk
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Integration of Synaptic Events
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Methods of reducing fever
Pharmacological Methods of Reducing Fever:
Schwarzschild Radius and Event Horizon
The minimum speed required to launch a projectile from the surface of an object to which it is gravitationally bound so that it eventually escapes the object’s gravitational field is called the escape velocity. The escape velocity is independent of the mass of the object. Merging the idea of escape...