Related Experiment Video
Updated: Feb 7, 2026

Designing Porous Silicon Films as Carriers of Nerve Growth Factor
Published on: January 25, 2019
Paeonol-Loaded Ethosomes as Transdermal Delivery Carriers: Design, Preparation and Evaluation
Hongdan Ma1, Dongyan Guo2,3, Yu Fan4
1Shaanxi Province Key Laboratory of New Drugs and Chinese Medicine Foundation Research, Shaanxi University of Chinese Medicine, Xianyang 712000, Shaanxi, China. mahongdancy@163.com.
Abstract:
Paeonol exhibits a wide range of pharmacological activities, such as anti-inflammatory, antidiabetic as well as pain-relieving activities. However, its intrinsic properties, such as low water solubility, poor stability and low oral bioavailability, restrict its clinical application. The current study aimed to optimize paeonol-loaded ethosomal formulation and characterize it in terms of encapsulation efficiency (EE), vesicle size (VS), zeta potential (ZP) and polydispersity index (PDI), in addition to differential scanning calorimetry (DSC), X-ray diffraction (XRD) and Fourier-transform infrared spectroscopy (FT-IR) studies. Here, paeonol-loaded ethosomes were prepared by the injection method and optimized by the single-factor test and central composite design-response surface methodology. The optimized paeonol-loaded ethosomes had an EE of 84.33 ± 1.34%, VS of 120.2 ± 1.3 nm, negative charge of -16.8 ± 0.36 mV, and PDI of 0.131 ± 0.006. Ethosomes showed a spherical morphology under the transmission electron microscope (TEM). DSC, XRD and FT-IR results indicated that paeonol was successfully incorporated into the ethosomes. In-vitro transdermal absorption and skin retention of paeonol from paeonol-loaded ethosomes were 138.58 ± 9.60 µg/cm² and 52.60 ± 7.90 µg/cm², respectively. With reasonable skin tolerance, ethosomes could be a promising vehicle for transdermal delivery of paeonol.
Related Concept Videos
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Design of Columns under an Eccentric Load
Carrier Transport
Drift Current:
The drift of charge carriers is started by an external electric field (E). Charged particles, such as electrons and holes, experience an acceleration between collisions with lattice atoms. For electrons, this results in a drift velocity (vd) given by:
The ADP/ATP Carrier Protein
Group Design

