Differences in biochemical markers between Heart-transplanted and Left Ventricular Assist Device implanted patients,
Vittorio Racca1, Paolo Castiglioni2, Claudia Panzarino3
1Santa Maria Nascente Institute IRCCS, Don Gnocchi Foundation, Cardiology Rehabilitation Department, Milan, 20148, Italy. vracca@dongnocchi.it.
Abstract:
Heart transplant (HTx) and left ventricular assist device (LVAD) implant are the best options for symptomatic end stage heart failure, but LVAD patients show lower rehabilitative outcome than HTx patients. To investigate the causes, we compared biomarkers levels and their association with rehabilitative outcome in 51 HTx and in 46 LVAD patients entering the same cardiac rehabilitation program. In both groups, routine biomarkers were measured at start (T1) and end (T2) of cardiac rehabilitation while homocysteine, leptine and IGF-1 were measured at T1 only. HTx patients had lower lymphocyte, platelets, glucose, total proteins and albumin at T1; differences with LVAD patients vanished during rehabilitation when new cases of diabetes were observed in HTx. By contrast, total cholesterol, LDL and HDL fractions, leptin and IGF-1 were higher in HTx patients. The increase from T1 to T2 in six-minute walking test distance, measure of functional rehabilitation outcome, was positively associated with homocysteine and IGF-1 levels in HTx patients. In conclusion, during rehabilitation care should be paid to the early occurrence of dyslipidemia and hyperglycemia in HTx patients, which also require a proper protein dietary support. IGF-1, dangerously low in LVAD patients, might contribute to their lower rehabilitative outcome.
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Anatomy of the Heart
Physiology of the Heart: The Cardiac Cycle
Diastole: The Relaxation Phase
During diastole, all four heart chambers relax. The atrioventricular (AV) valves open, and the semilunar valves close. This phase sees the lowest chamber pressures, promoting ventricular filling. Venous blood enters the heart through the...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Catheterization II: Right Heart Catheterization
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...