Related Experiment Video
Updated: Feb 7, 2026

Experimental Investigation of the Flow Structure over a Delta Wing Via Flow Visualization Methods
Published on: April 23, 2018
Experimental investigations of the aerated polymethylmethacrylate-based vertebral cement flow in capillaries
Zbigniew Tyfa1, Dariusz Witkowski1, Krzysztof Sobczak1
1Institute of Turbomachinery, Lodz University of Technology, Lodz, Poland.
Introduction:
A constant growth in the population suffering from osteoporotic vertebral weakening is observed. As a result, vertebroplasty procedures become more and more common. Unfortunately, they may be associated with several complications occurring during bone cement injection, including its leakage or overheating of tissues. Despite several experimental studies, there is a lack of data related to random aeration of the bone cement. Therefore, the main objective of the following investigations was to emphasize that random aeration of the bone cement, and, consequently, a compressibility factor, could not be treated as a negligible factor during the vertebroplasty procedure and had to be taken into account in the development of the mathematical model.
Materials And Methods:
A special test rig to reproduce the vertebroplasty procedure was designed and built. The authors conducted numerous experiments on polymethylmethacrylate-based bone cement flows, analyzing different flow conditions, such as volume flow rate and flow channel diameter. Time periods of the flow front between characteristic sections and pressures (differential and gauge) were measured.
Results:
All investigations revealed that bone cements mixed in special mixing kits were characterized by a random level of aeration which led to varied flow parameters. Comparing the experimental results with the theoretical values of the continuity equation, the highest difference in the flow duration reached 140%.
Discussion:
It has been proven that the aeration of the bone cement alters the flow dynamics. Therefore, much more data are required for statistical analysis to validate a mathematical model of the bone cement flow.
Related Concept Videos
Hydration of Cement
Soundness of Cement
Portland Cement
Fineness of Cement
Direct...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...

